Laserfiche WebLink
i <br /> i <br /> s Ouslift AssunweelOuality Conind Samples <br /> At a mimmum,amp blank and a temperature blank are maintained for QA/QC purposes <br /> Amp blank sample(TRIP)is kept with any samples being analyzed for VOCs <br /> This is a sample of clean water that is supplied by the laboratory and is <br /> transported to and from the field and to the laboratory with the field samples The <br /> designation"QCTRIPBK" or"QCTB" is used for sample name on the field label <br /> Samplers record the date that the TRIP is taken to the field for sampling,not the <br /> date that the TRIP was prepared by the laboratory on the chain-of-custody(COC) <br /> One TRIP per cooler per day is collected <br /> • Unused trip blank samples are stored at the consulting office in a cooler dedicated <br /> to this purpose The trip blank cooler is not refrigerated,but is kept in a clean <br /> location away from possible VOC contaminants <br /> • Temperature blank sample containers are supplied by the laboratory and kept in a <br /> cooler used to transport samples The temperature blank is placed in the cooler <br />' prior to going to the field and kept there until the cooler is delivered to the <br /> laboratory <br /> 9 Compketion of Ch n of Custody <br /> • A separate COC is completed for each day of sampling If samples are collected <br /> on separate days for the same site, a separate COC is completed for each sampling <br /> day,and the COC is always kept with the samples If samples are shipped off site <br /> for laboratory analysis,individual coolers with separate COCs are sent for each <br /> day/cooler shipped <br /> I All fields/spaces on the COC are filled out completely, and all persons having <br /> control of the samples sign the COC to show transfer of sample control between <br /> individuals At times when the field sampler is not delivering samples directly to <br /> the laboratory, the samples may be turned over to a sample manager for shipping <br /> In this instance,the sample manager takes custody of the samples, and both <br /> the sampler and sample manager sign and date the COC to clearly show custody <br /> transfer <br /> • The COC is placed inside the cooler, and a custody seal is placed on the outside <br /> of the coder prior to shipping The receiving laboratory indicates if the cooler <br /> was received with the custody seal intact. <br /> • If samples are sent to the laboratory via UPS,FEDEX,etc,this is indicated on <br /> the COC, and the sample manager indicates the date and time custody seal is <br /> placed on cooler for delivery to the shipping agent(shipping agent does not sign <br /> i the COC) <br /> • For trip blanks,the COC indicates the date the TRIP was taken to the field for <br /> sampling, not the date the TRIP was prepared by the laboratory, which may <br /> appear on the VOA label <br /> • New electronic deliverable format(EDF)regwrements of California AB2886 <br /> mandate that COCs and laboratory reports maintain consistent and unique names <br /> between sites (Global ID)and sample location/well names(Field Point ID) This <br /> information must be consistent with the initial mformahon supplied to <br /> Geotracker, and for each subsequent quarterly sampling event <br /> I <br /> I <br />