COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:44:25 PM
Creation date
5/7/2019 4:02:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si2ov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> Ooil 4 4MM-1ml e I g <br /> Facility address: UST# ' <br /> Product <br /> F o Contact: Title: Phone: , <br /> M,pgitoring Panel: Piping system: I Overfill prevention: <br /> VIVJ` 11A Pressurized ❑Suction ❑Gravity ❑Mechanical Audible/visual <br /> Inspection type: IViolations: <br /> Routine Monitoring Certification ❑Installation ❑Other: 1-RDetect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATION(S) HSC=California Health&Safety Code;CC =California Code of Regulations V R V=Violation;RV=R eat Violation V <br /> I HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b)& c) Current Unified Program Consolidated Forms on file with EHD(Facility and tank form) <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b) Monitoring Program(Monitoring&Res once Plan)is current and approved by the local agency. <br /> 6 1 CCR 2712(i) Monitoring Ian is onsite. <br /> 7 CCR 2712 b) Maintenance&monitoring records M1 <br /> 8 CCR 2643 d) Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (M 1) <br /> 1 1 CCR 2630 d) UST system monitoring equipment is properly located to detect a leak (M 1 <br /> 12 HSC 25291 b) UST system monitoring equipment isoperational (M2) <br /> 13 CCR 2636(t)(1) Continuous monitoring system for underground piping&UDC is present M 1 <br /> 14 CCR 2631 (a) Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636 c) 1) All releases in secondary piping flow to a collection sum <br /> 17 HSC 25291 t Line leak detector(s)are installed M1) <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (M 1 <br /> 23 CCR 2715 Designated Operator:(a)Statement from UST owner; (c-e)Monthly inspection; t)Employee training <br /> 24 CCR 2638 a) Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (M 1) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636(f)(4) Annual line tightness test M1) <br /> 28 CCR 2661 (f) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e) Biennial tihtness test of gravitypiping(pre-JanuaryI, 1984) <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-January 1, 1984) M1 <br /> 31 HSC 25292.5 Double wall-system located within 1000'of public well-ELD <br /> 32 CCR 2661 Pennit to repair UST system <br /> 33 HSC 25286 a) Permit to alter monitoring system lid <br /> 34 HSC 25298(b) Permit to temporarily close UST system <br /> 35 HSC 25298 c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) I Illegal abandonment of UST system <br /> 38 Other: <br /> EH I S CTO ONE: UIC <br /> J Septic s stem: <br /> Serves>_20 people/day <br /> RECM�, L —Receives other than sanitary waste <br /> Other disposal methods: <br /> Z — —Dry wells/French Drains <br /> EHD 23-02-002 REV 05/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.