My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:44:25 PM
Creation date
5/7/2019 4:02:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> SWRCB,January 2002 Page 9 of 10 <br /> S. FILL RISER CONTAI iWNT SUMP TESTING <br /> . Facifity is Not Equippcd With Fill Riser Containment Sums n <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: Sump Manufacturer X Tndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Sped) <br /> Test Equipment Used:lncon TS STS Equipment Resolution: <br /> Fill Sum —ILF.S. Fill Sum —P.F.& Pi 11 Sum - Fill Sum - <br /> Su Diameter; 42" 42" <br /> Sump Dqpthe 60" 62" <br /> Height from Tank Top to Top of 18" 18" <br /> Hi est Piping Penetration: <br /> Height from.Tank Top to Lowest 31" 32" <br /> Electrical Penetration: <br /> Condition of sump prior to Clean Clean <br /> test' <br /> Portion of Sump Tested Full Full <br /> Sump Material: Fiberglass Fiberglass <br /> Wait tinge between applying 15 minutes 15 minutes <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Stan Time: 11:21 11:21 <br /> Initial Reading 7.2902" 5.0862" <br /> Test End Time: 11:36 11:36 <br /> Final Reading 7.2893" 5.0856" <br /> Test Duration: 15 minutes 15 minutes <br /> Chane in Readin r-R : .0009" .0006" <br /> PassfFail Threshold or Criteria: Loss<.002"— s Loss<.002"— ass <br /> Test Result X Pass ❑Fail X Pass ❑Fail Ei Pass f_t Feil D ]peas C1 Fail <br /> Is there a sensor in the sump? X Yes ❑No X Yes 7-1 No ©Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when. <br /> either product or water is X Yes ❑No ❑NA X Yes C No 0 NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? X Yes 7-No 0 NA X Yes ❑No ❑NA ❑Yes ❑No C NA l7 Yes C No 0 NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No DNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> COWM4 tlltS—(include information on repairs made prior to testing, and recommended follow-rip for farled tests) <br /> Test repeated from 3-22-06 in order to keep all components current. <br />
The URL can be used to link to this page
Your browser does not support the video tag.