Laserfiche WebLink
Integrated solutions for centralized , <br /> single system vapor recovery <br /> TLS Monitoring System Requirements <br /> ISD is compatible with the TLS-350/EMC wBIR, TLS-350 - <br /> Plus/EMC Enhanced,TLS-350/EMC consoles with the following ` 5 <br /> minimum requirements/features: l A specially designed vapor flow meter accurately <br /> measures the amount of gasoline vapor returning <br /> • ECPU2 and TIS console version 25C software(or greater) 'r,4 p«aT r. from the car allowing the system to identify a failed <br /> • RS-232 Interface,for example:a RS-232 Interface Module,a 7 or degrading component. <br /> Dual-Port RS-232/RS-485 Interface Module,etc. ' <br /> • Dispenser Interface Module(DIM) <br /> • Submersible Turbine Pump(STP)shutdown control hardware, <br /> for example:a Four-Relay Output Interface Module,a Three <br /> Output Pressurized Line Leak Control Module(must be used in <br /> conjunction with PLLD),etc <br /> A pressure sensor is installed in the <br /> • TLS console must have and integral printer,probes and the containment system to monitor tanks W g17E 4 m <br /> appropriate number of sensor interface modules pressures 24 hours a day to ensure s p <br /> proper containment of the gasoline >' <br /> vapors. <br /> Alarm Table 00-00 <br /> The following table contains a list of warnings and alarms ISD System Requirements <br /> generated by the ISD system. The following table contains pricing, part numbers as well as a description for the <br /> Warning Days to Description ISD components. <br /> Alarm <br /> ISD DEGRD PRESSURE 30 Vapor Overpressure Problem Part No. Description "Monitored Item(s) <br /> ISD GROSS PRESSURE 7 Vapor OveressureProblem 330020-445 Vapor Floc Meter(sensor) Kit 1 per dispenser <br /> ISD VAPOR LEAKAGE 7 Vapor Leakage Problem <br /> ISD SENSOR OUT 7 Sensor Problem 330020-515 Vapor Pressure Sensor Kit' 1 per station <br /> ISD SETUP 7 Setup Problem 331943-203 NVMEM 2(Report Storage) 1 per console <br /> Hnn:DEGRD COLLECT 7 Hose A/L Problem 330160-xxx Software Enhancement Module(SEM) 1 per console <br /> Hnn:GROSS COLLECT 1 Hose Blockage or A/L Problem <br /> :FLOW COLLECT 1 Hose Blockage Problem 'Tht vapor flow meter and vapor pressure sensor are intrinsically safe sensors that connect to either the Eight Input <br /> HnnF <br /> ISD STATUS 1HVapor Processor Problem Smart Sensor Interface Module(P/N 329356-004)or the Seven Input Smart Sensor Module w/Embedded Pressure <br /> Sensor Interface Module(P/N 332250-001.) <br /> ISD VP PRESSURE 1 Vapor Processor Problem <br /> 'The vapor pressure sensor kit includes ISD system manuals. <br /> Typical installation <br /> The following figure MPaivii5vi,,P, <br /> shows a typical ISD <br /> installation in the base of <br /> a dispenser. <br /> eAEr Pressure sen port Vapw r,W rine <br /> lrwn dspenser <br /> ISD FI—Mete, <br /> (^rala11B4 amyrtrere <br /> Amwmpst `d' Caae (supplied) <br /> to•o0 <br /> POM III- <br /> 7d U01V <br /> reapirea <br /> _ = Seal dl <br /> PKC b Vapor return Irre Icusromee <br /> WTIET Train ll4• srwar sOpplredl <br /> Flwv macer em clew hocen rEonbl <br /> Conduit ro <br /> TLS Console <br /> TW dped"M OW4 <br /> A lest port k re .d br <br /> MrudWN fp,W during Fk Meter and Pressure <br /> TP 201 A dyramp Say wrriM may dare <br /> tle 1Qlreseure bst Te same mMul ro<aaale <br /> For more information call <br /> 2•pr 3•mnmon main vapor,Num M1ne <br /> a 1-888 56_i 79142 <br /> '` VEEDER-ROOT ®2005 Veeder-Root Company 125 Powder Forest Drive Simsbury,CT 06070 • USA <br /> 41111h.,I Telephone:860-651-2700 • Fax:860-651-2719 • www.veeder.com <br /> VR 13753 P/N 0576047-065 Rev.B Printed in USA <br />