Laserfiche WebLink
r ' <br /> BLAINE 1680 ROGERS AVENUE <br /> TECH SERVICES. SAN JOSE,CA 95112-1105 <br /> (408)573-7771 FAX <br /> ao M (408)573-0555 PHONE <br /> CONTRACTOR'S LICENSE#746684 <br /> www blametech com <br /> �l <br /> January 11, 2001 <br /> Karen Petryna <br /> Equiva Services LLC <br /> P O Box 7869 <br /> Burbank, CA 91510-7869 <br /> Fourth Quarter 2000 Groundwater Monitoring at <br /> Former Shell Service Station <br /> 880 Victor Road <br /> . Lodi, CA <br /> Monitoring performed on November 20, 2000 <br /> Groundwater Monitoring Report 001120-J-2 <br /> This report covers the routine monitoring of groundwater wells at this Fortner Shell facility In <br /> accordance with standard procedures that conform to Regional Water Quality Control Board <br /> requirements,routine field data collection Includes depth to water, total well depth, thickness of <br /> any separate immiscible layer, water column volume, calculated purge volume (if applicable), <br /> elapsed evacuation time(If applicable), total volume of water removed(if applicable), and <br /> standard water parameter instrument readings Sample material Is collected, contained, stored, <br /> and transported to the laboratory In conformance with EPA standards. Purgewater(if applicable) <br /> Is, likewise, collected and transported to the Martinez Refining Company <br /> Basic field information Is presented alongside analytical values excerpted from the laboratory <br /> report in the cumulative table of WELL CONCENTRATIONS The full analytical report for <br /> the most recent samples and the field data sheets are attached to this report <br /> At a minimum, Blaine Tech Services, Inc field personnel are certified on completion of a forty <br /> hour Hazardous Materials and Emergency Response training course per 29 CFR 1910 120 Field <br /> Personnel are also enrolled in annual eight hour refresher courses <br />