My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0009020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2900 - Site Mitigation Program
>
PR0503634
>
ARCHIVED REPORTS XR0009020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2019 4:58:59 PM
Creation date
5/7/2019 4:45:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009020
RECORD_ID
PR0503634
PE
2950
FACILITY_ID
FA0005914
FACILITY_NAME
VICTOR ROAD SHELL
STREET_NUMBER
880
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905032
CURRENT_STATUS
02
SITE_LOCATION
880 VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CAMBRIA <br /> Table 3. Soil Vapor Extraction Test Radius of Influence Data,Fortner Shell Service Station/Econo Gas, 880 Victor Road, Lodi, California <br /> Extraction Monitoring Rw r Pw(in WC) P(r)in WC Patin in WC Ri Screen <br /> Well Wells (ft) (ft) gauge absolute gauge absolute absolute (ft) Exposed(ft) <br /> SVE-1 Vacuum readings at observation wells collected at 12 44 October 7,2003 <br /> SVE-1 SVE-2 0 167 160 159 3909 05 4063 4068 186 15 <br /> SVE-1 SVE-3 0 167 420 159 3909 00 4068 4068 -- 15 <br /> SVE-2 Vacuum readings at observation wells collected at 9 40 October 9,2003 <br /> SVE-2 SVE-1 0 167 160 13 4 393 4 06 4062 4068 199 15 <br /> SVE-2 SVE-3 0 167 370 134 3934 00 4068 4068 -- 15 <br /> Based on the steady-state radial pressure distribution equation from"A Practical Approach to the Design,Operation,and Monitoring of In Situ Soil Venting Systems", <br /> P C Johnson,C C Stanley,M W Kemblowski,D L Byers,and J D Cothart,Groundwater Monitoring and Review Spring 1990 <br /> Rt=(Rw]/(r/Riv]^((1-(PatmVPw)^2J/(((P(r)/Pw)^2)-II] <br /> Note Vacuum influence was not detected in wells SVE-1 or SVE-2 when extracting soil vapors from SVE-3 <br /> Rw=Radius of Extraction Well(feet) <br /> r=Distance of monitoring well from extraction well(feet) Distances based on the site map and verified in the field <br /> Pw=Absolute pressure applied at extraction well(inches of water column) <br /> P(r)=Absolute pressure at monitoring well(inches of water column) <br /> Patm=Absolute atmospheric pressure(406 8 in WC) <br /> Ri=Radius of Influence(feet) <br /> 0955 Page ] of 1 <br />