My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MUNFORD
>
3730
>
2800 - Aboveground Petroleum Storage Program
>
PR0531150
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 1:50:57 AM
Creation date
5/10/2019 8:51:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0531150
PE
2832
FACILITY_ID
FA0014437
FACILITY_NAME
Intermodal 1
STREET_NUMBER
3730
Direction
E
STREET_NAME
MUNFORD
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
17956010
CURRENT_STATUS
01
SITE_LOCATION
3730 E MUNFORD AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N.J O A Q U IN Environmental Health Department <br /> —COUNT Y--- <br /> Greatness grows here <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> NORCAL TRANSPORT REFRIGERATION (209)466-4816 May 09, 2019 <br /> Facility Address: CERS ID: <br /> 3730 E MUNFORD AVE, STOCKTON, CA 95215 10184669 <br /> Inspection Contact: Title: Phone: <br /> Bob Carsey President (209)466-4816 <br /> Inspection Type: Program: <br /> ROUTINE SUPPLEMENTAL ACTIVITY-Operating Permit 2832-AST FAC 10 K-</=100 K GAL CUMULATIVE <br /> Consent For: Consent Given By: <br /> ❑O Ins ection [KPhotos ❑ Sam le I Bob Carsey, President <br /> CCR=California Code of Regulations HSC=Health and Safely Code CFR=Title 40 Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during <br /> Aboveground Petroleum Storage Act <br /> 101 HSC 25270.6(b) Failed to pay APSA program annual fees n V o R o COS <br /> 102 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 ❑V c R o COS <br /> 103 HSC 25270.6(a) Failed to file HMBP or annual facility tank statement ■V o R o COS <br /> 104 HSC 25270.8 Failed to report spills or releases of 42 gallons(one barrel)or more o V o R o COS <br /> 105 CFR 112.1(b)(3),112.2 Failure to properly close tanks when making a claim of permanently closed o V o R o COS <br /> 106 HSC 25404.1.2 Failed to submit a certification and written response within 30 days for minor violations o V o R n COS <br /> 107 HSC 25270.2(a)(4) Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion o V o R n COS <br /> 108 HSC 25270.4.5(a) Failure of conditionally exempt facility to conduct inspections or install secondary containment o V ❑R ❑COS <br /> 109 HSC 25270.2(o)(1)(C) Failure to have secondary containment and/or leak detection if TIUGA piping cannot be viewed c V ❑R ❑COS <br /> (iv)(111) <br /> 110 HSC 25404(e)(4) Failed to report program data in the California Environmental Reporting System(CERS) o V o R o COS <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112.3(d) Failure to have a licensed PE properly review and certify the SPCC plan o V n R n COS <br /> 202 CFR 112.3(e)(1) Failed to maintain a copy of the Plan on site n V a R c COS <br /> 203 CFR 112.3 Failure to implement the SPCC Plan o V o R o COS <br /> 204 CFR 112.3(g) Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria c V o R o COS <br /> 205 CFR 112.3,112.6 Failure to prepare SPCC Plan that meets all applicable requirements n V ❑R o COS <br /> 206 CFR 112.3(d)(1) Failure of owner to assure that the PE makes all required attestations in the Plan ❑V o R o COS <br /> Amendment of SPCC Plan by Owners or Operators <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary V Li R o COS <br /> 302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments o V c R c COS <br /> 303 CFR 112.5(c) Failed to have a PE certify technical amendments o V o R ❑COS <br /> 304 CFR 112.5(a), 112.5(b) Failure to implement SPCC plan amendments within 6 months ❑V ❑R o COS <br /> Qualified Facility-Tier 1 <br /> 401 CFR 112.6(a),112.6(b) Tier I Qualified Facility Plan not certified by the owner or a PE o V n R n COS <br /> 402 CFR 112.6(a)(2) Owner of Tier I Qualified Facility failed to self certify technical amendment o V o R c COS <br /> 403 CFR 112.6(a)(3)(i) Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged o V o R o COS <br /> 404 CFR 112.6(a)(3)(ii) No 2CT for bulk containers,or mobile storage containers not located to prevent discharge o V o R o COS <br /> FA0014437 PR0531150 SCO02 05/09/2019 <br /> EHD 2M1 Rev.09/27/2018 Page 1 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page