My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
INSTALL 1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 11:44:00 AM
Creation date
5/10/2019 2:21:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6.4 SUBSURFACE SOIL CONDITIONS <br /> JThe site is underlain by Holocene dune sand and alluvium consisting of interbedded sands, <br /> J silts and clays. The upper 15 feet consist primarily of sand and interbedded silts and clays <br /> generally occur below this depth. <br /> 7 6.5 GROUNDWATER CONDITIONS <br /> Groundwater was measured at 15.75 to 16.73 feet bgs in the onsite monitoring wells MW-1, <br /> MW-2 and MW-3. The measured groundwater gradient flows southwest at 0.00547 ft/ft <br /> which is generally consistent with the known regional gradient direction. Discussions with <br /> agencies indicate regional groundwater flow is northwest, but generally westward. <br /> J <br /> 6.6 ANALYTICAL TEST RESULTS <br /> 6.6.1 PID Field Readings <br /> Volatile organic vapor readings were not detected by an Hnu PID in the subsoil samples <br /> obtained from the exploratory borings at the time of drilling, nor were odors or other <br /> hydrocarbons noted during drilling. The PID readings are noted on the boring logs attached <br /> as Appendix B. <br /> J6.6.2 Soil Samples <br /> The laboratory test results indicated non-detectable concentrations of TPH, BTEX, and <br /> MTBE in the composite soil samples. Soil test results are summarized in Table 1 and the <br /> analytical laboratory report is included in Appendix C. <br /> —� 6.6.3 Groundwater Samples <br /> The groundwater sample obtained from well MW-2 shows concentrations of 1.6 ug/L(ppb) <br /> l benzene, 15 ppb ethylbenzene, 13 ppb xylenes and 0.330 mg/L (ppm) TPH. The other <br /> ,J groundwater samples (MW-1, MW-3 and hydropunch SB-1) show non-detectable levels of <br /> _ TPH and BTEX. All groundwater samples analyzed show non-detectable concentrations of <br /> MTBE- The groundwater samples MW-2 and MW-3 show non-detectable concentrations of <br /> volatile organic compounds by method 8260. The MW-2 sample showing non-detectable <br /> concentrations by 8260 and detectable concentrations by methods 8015-8020 is not consistent. <br /> Groundwater test results are summarized in Table 2 and the analytical laboratory report is <br /> included in Appendix C. <br /> -� IN 40007-097-01 <br /> aec-%\.r=cea.eu 6-2 <br />