My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2006 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
BILLING 2006 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 12:49:00 PM
Creation date
5/10/2019 4:02:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2006 - 2011
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
low <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS Tkn)iL- ► <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT S.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT <br /> ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NA ME nr DBA-Doing Business As) 3. FACILITY ID: 1 <br /> S-meET /> L0 1• M Doh-;cis 2�I[cF9M5i � � 0 � � ¢ <br /> .,., <br /> LOCATION WITHIN SITE(Optional) 431 <br /> hoo S. MAi►J S7(ZEET Mkt,1TEc.A, CA 9532,-1 <br /> I TANK DESCRIPTION <br /> (A scaled.plot plan withahe IocaHon of the USTystem.lncludi'ng buildings and landmarks shall be submitted to the local aggney.;)' . <br /> TANKID# 432. TANK MANUFACTURER 433 COMPARTMENTALIZED TANK El Yes No 434. <br /> V N L e k,OE /,EIZ)�E S If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEAR/MO 437. <br /> Jqcg 10-1 20,oo0 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II'TANK:CONTENTS i <br /> _ r <br /> TANK USE 439. PETROLEUM TYPE 440. <br /> 1t'l 1. MOTOR VEHICLE FUEL Kla. REGULAR UNLEADED [12. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED <br /> ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑ 1 c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441' CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used NO <br /> ❑ 95.UNKNOWN. b I <br /> III TANK CONSTRUCTION F. r <br /> TYPE OF TANK ❑ I. SINGLE WALL C]3. SINGLE WALL WITH EXTERIOR El 5. SINGLE WALL;;,• ..,... ,• :_- E 4,. <br /> WITH INTERNALLBLADDER SYSTEM 4<3. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primarytank ❑1. BARE STEEL X3. FIBERGLASS/PLASTIC [15. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑ 1. BARE STEEL . FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑3.EPDXY LINING p 5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING X6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑ 1.MANUFACTURED CATHODIC 193.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION FOI gPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) )9 2l.SPILL CONTAINMENT 2.004- I.ALARM 200+MS.FILL TUBE SHUTOFF VALVE <br /> 2.DROP TUBE 04 2.BALL FLOAT LO o4 ❑4.EXEMPT <br /> 3.STRIKER PLATE <br /> LV'TAN <br /> K LEAK DETECTION r <br /> (A description of the monitoring program shall bi;l,subin,ttttjd to the local agency:) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE 'X 2.CONTINUOUS INTERSTITIAL MONITORING <br /> [13. CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MA?s IAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN.PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 45z <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidoes.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.