My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1997 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
BILLING 1997 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 12:40:34 PM
Creation date
5/10/2019 4:17:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1997 - 2005
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tspunccs <br /> STATE OF CALIFORNIA cOa, <br /> STATE WATER RESOURCES CONTROL BOARD V m <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> o <br /> •C�I.i OA H� <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT 7] 4 AMENDED PERMIT ED TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED 1 <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: fi ,Co /►� e L (p 3 J' �tslq - I <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# ' B. MANUFACTURED BY: x E <br /> C. DATE INSTALLED(MO/DAY/YEAR) 'jZ'l q7 D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> q � 1 MOTOR VEHICLE FUEL F-1 4 OIL B. C ❑ 1a REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> is MIOGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE 17 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM 0.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF j< 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL K 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLEW/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN ® 99 OTHER—� � <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES, NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BtC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL P EVENTION EQUIPMENT INSTALLED(YEAR) 22 7 <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A PRESSURE A U 3 GRAVITY 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U i SINGLE WALL A DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A® FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> MECHANICAL LINE LEAK 2 LINE T 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC LINE 5 AUTOMATIC PUMP gg OTHER <br /> D. LEAK DETECTION DETECTOR [:] TESTINGIGHTNESS MONITORING ❑ LEAK DETECTOR SHUTDOWN ❑ <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK E] 2 MANUAL INVENTORECONCILIATION RY ❑ 3 MONITORING VADOZE ❑ 4 GAUGING AUTOMATIC TANK E::] 5 MON TORINGGROUND WATER E:] 6 TESTINGANNUAL <br /> �7 MONITORING INTERSTITIAL ❑ 8 SIR ❑ 9 WEEK LY MANUAL ❑10 T ONTHLY TANK El 95 UNKNOWN [:199 OTHER <br /> NG <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) p� A- <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO ❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME `A�`L/y J � ���� DATE <br /> (PRINTED 8 SIGNATURE) �/y{�{'�, / v <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY#1 TANK# 00 1 <br /> STATE I.D.# m <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE I <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT P' FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THF"-"ERGROUND STORAGE TANKREGULATIONS^ <br /> FORM B (6.95) 1 +� I w <br />
The URL can be used to link to this page