My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 11:22:26 AM
Creation date
5/13/2019 8:45:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I , ' <br /> MONITuRING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited-Chapter 6.7, Health and Safety Code; Chapter T,5, Division 3, Title 23, California Code of Regulations <br /> "iis form must he used to document testing and servicing of monitoring equipmt.nt- <br /> ,e.�;}�y;..�p�r a "station or re}�o, r�a��tst be oreoarod for ems:'-ng�.�`dgtn�ptrol n by the technician who performs the wort:,. <br /> A copy of this form must be provided to the tank system owner/ope.ator. The must submit a copy 4f tk!LIEr t ►ma y_i <br /> regulating UST sysmias within 30 days of test date. `¢ ' <br /> JUN 0 7 2016 <br /> A. Genend Information • r'*�rK. �►�- <br /> Facility Name: <br /> C'itvl4'rw �l 'Site Address: — ---• <br /> Facility Contact Person: Contact Phone No.: <br /> Make/Model iodel of Monitoring System: j- . Date of Testing/Servicing: <br /> B. Inventory of Equipment TesteWCertified f <br /> Check the 6propriste boxes to indicate s IIc equipment Inspected/se,vicetFt: <br /> Tank ID: Tank ID: <br /> ❑in-Tank Gauging Probe. _Model: _ 1,t-Tank Gauging Probe. Model: <br /> )(Annular Sparc or Vault Sensor. Modes:"'° _____ A.nrtular Space or Vault Sensor. Model: <br /> Piping 5urrsp/Trench Sensor(s). _ Esping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: _ bili Sump Sensor(:). Modes: MF �mobanieal Line Leak Detector. Model: 11}�[�,© � Xld�i�Line�Detector. Model: <br /> ❑glectronic Line Leak Detector. Model: _ ❑1:1ectronic Line Leak Detector. Model: <br /> Tank Overfill I High-Level Sensor. Model: Aw a*overfill/High-Level Sensor. Model: <br /> Other(specify eq►tVaient type and model in Section on Page 2). )ever(specify equipment type and model in Section Page 2). <br /> Tank 11D: —L Tank ID: <br /> ❑In-Tanis Gauging Probe. Model: _ _ ❑ n-Tank Gauging Probe. Model: <br /> 49 Annular Space or Vault Sensor. Model: ❑ knnular Space or Vault Sensor. Model: <br /> 1%Piping Sump/Trench Sensor(s). Model:-- _ [3 'iping Sump I Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model:5 ❑ 7-ill Sump Sensor(s). Model: <br /> Modmicai Line Leak Detector. Model: ❑ viechanical Line Leak Detector, Model: <br /> Electronic Line Leak Detector. Model: _ ❑ lectroaic Line Leak Detector. Model: <br /> a Tank Overfill/High-i evel Sensor. siodeltim ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑Ocher(specify equipment type acid model in Sectiolft on Page 2). [3- (specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: )"" 9 Dispenser M. <br /> Dispenser Containment Sensor(:). Modcl: "" 7. Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> ❑Dispenser Conuunmcnt Floats)and Chain(s). ❑Dispenser Containment Float(s)and Chtin(s). <br /> DispenserID: i D* penser ID: +� <br /> Dispeam Gomai»eat Smsor(s). Model: - 52Z Dispenser Containment Sensor(s). Model: .�- <br /> Shear Valve(s). ❑shear Valve(s). <br /> ❑Dispcn=Containment Floats)and Chnin(s)- ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: " L Dispenser ID: -"� • <br /> DispenserContainment Sensor(s). Model:-.-WS r. RIDispense'Comainment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Disperser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form Include infommuon for every tank and dispenser at the facility. <br /> C. CertlfiCatlon-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines° Attached to this Certification Is information (e.g. manufachnWs' checklists) necessary to verify that this information is <br /> correct and a Site-Piot Plan showing the layout of monitor ing wpa-ent. For any eqgipment capable of geeeratir tech rqWr I have <br /> also attached a copy of the report;(clrack aU that q ply): Sy item set-up Ala to -�, ,�. <br /> WA <br /> Technician Flame(pr:itt): Tony Fontana S guawre: <br /> Certification No.: V.R.A23888 ICC 52882274UT L:sense.No.: A-848 <br /> Testing Company Mame: U.S.T.Couppaime Testing Inc. Phone No.:(249) 596.4489 <br /> Testing Company Address: P.O.Box WO Coms,CA 95307 Date of Tesd*Servicing: •" <br /> ups-ou-rib -uasdac--nom <br />
The URL can be used to link to this page
Your browser does not support the video tag.