Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s'gov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faculty Main Street Arco Facility 1100 S Main Street, Manteca Inspection Mar 18, 2014 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code,CFR=Code of Federal Regulations <br /> C1 =Class 1 violation,C2=Class 2 violation:M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mi) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Onsite to conduct a routine underground storage tank inspection and observe monitoring system <br /> certification conducted today. Inspection was performed on March 18, 2014, the checklist of findings <br /> was provided the same day; the full inspection report was mailed to the facility on March 24, 2014. <br /> Class II Violations: 104 and 310 <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Current financial responsibility <br /> documents were submitted to the EHD at the time of inspection. Alternatively in the future, log into <br /> CERS, upload the required information, and submit for review by the EHD. CORRECTED. <br /> 310. Liquid was observed in the 91-octane (less than 1 cup) and 87-octane fill (approximately 1/2 gallon) <br /> sumps. If water could enter into the secondary containment by precipitation or infiltration, it must be <br /> removed and disposed of properly. The technician onsite removed the observed liquid and placed it in <br /> the onsite hazardous waste drum. Ensure that all fill sumps are maintained free of liquid. CORRECTED. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By: Title: <br /> -�Jena 0A(an U-4 - rna-, ( � <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />