Laserfiche WebLink
MONITOUNG SYSTEM CERTIFI :TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code 16140 W.$P � <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must he pre @ 1d <br /> or <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. MA'Y' 14 2012 <br /> A. General Information <br /> ENVIRONMENTAL HEALTH <br /> Facility Name: Arco Bldg. NPM1T/SERVICES <br /> Site Address: 1100 S. Main St. City: Manteca Zip: 95337 <br /> Facility Contact Person: Jessie Contact Phone No.: (209) 609-0117 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 3/30/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: T1: 87 Tank ID: T2: 91 <br /> Z In-Tank Gauging Probe. Model: 847390-109 Z In-Tank Gauging Probe. Model: 847390-109 <br /> Z Annular Space or Vault Sensor. Model: 794390-409 Z Annular Space or Vault Sensor. Model: 794390-409 <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 Z Piping Sump/Trench Sensor(s). Model: 794380-323 <br /> Z Fill Sump Sensor(s). Model: 794380-323 Z Fill Sump Sensor(s). Model: 794380-323 <br /> Z Mechanical Line Leak Detector. Model: 99LD-2000 Z Mechanical Line Leak Detector. Model: FE STP-MLD <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: 89 Tank ID: <br /> Z In-Tank Gauging Probe. Model: 847390-109 ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 ElPiping Sump/Trench Sensor(s). Model: <br /> Z Fill Sump Sensor(s). Model: 794380-323 ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: FE STP-MLD ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 18x2 Dispenser ID: 384 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 58x6 Dispenser ID: 788 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containfient Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9810 Dispenser ID: 11812 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - t certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): Z System set-up Z Alarm histo report <br /> Technician Name(print): Guadalupe SanchezSignature,•,_ <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No.: (209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd. Oakdale, Ca.95361 Date of Testing/Seryicing: 3/30/2012 <br /> Page 1 of 4 <br /> Rev(2/08) <br />