My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
5000
>
2800 - Aboveground Petroleum Storage Program
>
PR0527046
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2019 9:20:08 AM
Creation date
5/13/2019 9:06:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527046
PE
2832
FACILITY_ID
FA0003907
FACILITY_NAME
PANELLA TRUCKING LLC
STREET_NUMBER
5000
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14330001
CURRENT_STATUS
01
SITE_LOCATION
5000 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> f <br /> The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for PANELLA TRUCKING LLC as of May10, 2019. <br /> i <br /> I <br /> Open violations from October 19, 2018 inspection <br /> Violation #301 -Failed to amend Plan as necessary. <br /> Page 5, section 2.5, of the SPCC plan states that the facility meets the criteria of a Tier II qualified facility. The I <br /> facility does not qualify for Tier II requirements based on the aggregate storage capacity of the facility being over <br /> 10,000 gallons. Page 10 of the SPCC plan states that storage drums are not addressed in the plan as they are not <br /> utilized for oil storage. Based on observations made at the facility and other sections of the plan, 55 gallon drums f <br /> are used for the storage of petroleum product. Page 20, section 4.2.4 of the plan, which addresses 40 CFR <br /> 112.8(c)(3), states that the section does not apply as berms are not utilized at the facility for secondary containment. <br /> Several tanks were observed to to have a diked area as secondary containment and is described in other sections <br /> of the plan. The Spill Prevention, Control, and Countermeasure (SPCC) Plan must be amended when there is a <br /> change in the facility design, construction, operation, or maintenance that materially affects its potential for a <br /> discharge, within 6 months of the change, and implemented as soon as possible, not later than 6 months following <br /> preparation of the amendment. Immediately make all necessary amendments to the SPCC Plan to accurately <br /> represent the procedures and policies currently in place at the facility. <br /> Note: A 100 gallon used oil container was removed from the facility within the last 6 months. <br /> Violation #603 -Failed to adequately describe the physical layout of the facility in the Plan. <br /> The storage area where mobile or portable containers are located was not included in the facility diagram. The Spill <br /> Prevention, Control, and Countermeasure (SPCC) Plan shall include a facility diagram which must mark the location <br /> and contents of each fixed storage container and the storage area where mobile or portable containers are located. <br /> It must identify the location of and mark as"exempt" underground tanks. It must also include all transfer stations <br /> and connecting pipes, including intra-facility gathering lines. Immediately update the facility diagram to include all of <br /> the required information. Submit a legible copy of the updated facility diagram,to the EHD for review. <br /> Violation #609 - Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure (SPCC) Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge. The 24 hour phone number for the San Joaquin County <br /> Environmental Health Department provided in the SPCC plan is incorrect. If a response plan was not submitted to j <br /> the Regional Administrator, this information must be included in the SPCC Plan Immediately amend the SPCC j <br /> Plan to include this information and submit a copy of the revision to the EHD. <br /> Violation #706 - Failed to provide and maintain adequate secondary containment. <br /> The areas referred to as West Tank Farm and East Tank Farm were observed with insufficient secondary <br /> containment. The wall providing secondary containment for the up t0 10,000 gallon tanks were observed to have i <br /> holes at ground level next to the corners. The circular holes of approximately one inch in diameter where observed <br /> near corners of the containment wall and traversed the entire wall. Construct all bulk storage tank installations <br /> (except mobile refuelers and other non-transportation-related tank trucks) so that you provide a secondary means of <br /> containment for the entire capacity of the largest single container and sufficient freeboard to contain precipitation. <br /> You must ensure that diked areas are sufficiently impervious to contain discharged oil Dikes, containment curbs, <br /> and pits are commonly employed for this purpose. You may also use an alternative system consisting of a drainage <br /> trench enclosure that must be arranged so that any discharge will terminate and be safely confined in a facility <br /> catchment basin or holding pond. Immediately provide secondary containment that sufficiently impervious to <br /> contain discharged oil and is capable of containing the entire capacity of the largest single container and sufficient <br /> freeboard to contain precipitation. <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.