Laserfiche WebLink
DATE <br /> SAN JOAQUIN COUNTY PR# <br /> ENVIRONMENTAL HEALTH DEPARTMENT PAGE \ oP 1 <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209) 468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> FFacilityName�+ _ �dy _FacilityAddress ` � RI!Wt�c k� Ooa <br /> Tltlersx t�e._>/��'- Phone# 9a L�t - kN ��Z�— <br /> ducts_ UST#aProduct�\ UST#}Product �- <br /> UST# ProductMonitoring Panel:ion: 2�AudibleNisy�I ❑ Mechanical Violations: nor ❑ Major <br /> : Gravity cXPressure G Suction // <br /> Automatic Pump Shut D wn Satis es CCR 2636 (g): <br /> yVes❑No D' penser Pan: as ❑ No <br /> INSPECTION TYP i�T\onitoring Certification EComplaint - stall []Removal PHONE:epairl�Up�g\rade -, <br /> COMPANY NAME: sy4�VS TECHNICIAN NAME:�\.1"Vs'\FA0� <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 20—CCR 2712 (b) Maintenance&monitoring <br /> 1 HSC 25284 Permit to operate records <br /> 2 CCR 2637 Secondary cont testing (6 21 CCR 2636 (f)(4) Annual line tightness test <br /> month/36 month) 22_CCR 2630 (d) Annual line leak detector test <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 23CCR 2630 (d) Annual monitoring certification <br /> 4�HSC 25292.2 Certification of financial 24_CCR_ 2643 (d) Daily monitoring of suction <br /> responsibility and letter from piping that is not continuously <br /> chief financial officer monitored <br /> 5 CCR 2630 (d) Continuous monitoring system 25_CCR 2636 (a) Conventional suction piping <br /> for UST system shall have continuous <br /> 6 CCR 2636 (c)(1) All releases in secondary piping monitoring & 20 containment <br /> flow to a collection sump Biennial tightness test of gravit. <br /> 7 HSC 25291 (e) Water in secondary (20) cont 26_CCR 2643 (e) 9 <br /> piping that is not continuously <br /> g HSC 25291 (f) Automatic line leak detector(s) monitored <br /> g CCR 2636 (f)(1) Continuous monitoring system 27_CCR 2662 Upgrade requirements for UST <br /> for underground piping system <br /> 10_CCR 2632 (c)(2) Continuous monitoring system <br /> for UST 28_CCR 2661 Permit to repair UST system <br /> 11_HSC 26291(a)(2) Secondary containment for 29 HSC 25286 (a) systePermm to alter monitoring <br /> UST is tight <br /> 12—CCR 2636 (f)(1) - Continuous monitoring system 30_HSC 25298 (a) Illegal abandonment of UST <br /> system <br /> for dispenser system 31_HSC 25298 (b) Permit to temporarily close USI <br /> 13 CCR 2635 (b)(1) Spill container system <br /> 147--CCR 2635 (b)(2) Overfill prevention system permit to close UST system <br /> 15_CCR 2631 (a) Primary containment is product- 32—HSC 25298 (c) Water in 20 cont analyzed and <br /> tight 33_HSC 25291 (e) properly disposed of <br /> 16—HSC 25292.1 UST system is operated to Single wall component within <br /> prevent unauthorized release 34_CCR 2640(e) 1000' of Public Well, no ELD <br /> 17_CCR 2650 Recording/reporting <br /> / unauthorized release 35_CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 / CCR 2632 (d) Monitoring & response plan 36_H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19CCR 2712 (i) Monitoring & response plan is 37_ <br /> Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR: PHONE: VtiCS <br /> TITLE: ©pe'� <br /> RECEIVED BY: <br />