Laserfiche WebLink
COLUMN BASE 2'-B" 6RADE BREAK 1 - <br /> COLUMN GLADDIN6 GLR. <br /> I <br /> COLUMN d _ — �: _. _ O LENS & 400W MH��AAMP f <br /> DISPENSER 1 _ ® 1 � rV <br /> / LIGHT POLES 2"x4"x.12" <br /> HIGH . WAY <br /> 5'-0" _ c-.._.. 4' L DISCHARGE A} <br /> EXPANSION NOTE: <br /> JT. (TYPJ4= COL. ¢ D15PEN5ER I. DISPENSERS SHOWN HAVE A Water <br /> WA <br /> WHIP I AIR d TER SIGN <br /> TOP H05E MOUNT. <br /> MU <br /> LTI-PRODUG7 FUEL 12 HOSE 2. SEE SHEET F53 FOR SUMP DETAILS <br /> DISPENSER GUARD POSTS BREAKAWAY <br /> NOTE: <br /> OPTION #1 (PREFERRED WHEN ALLOWED 3. MAXIMUM CENTERLINE HEIGHT OF SENTRY LIGHTING SYSTEMS SERIES ALL WATER PIPING SHALL <br /> o OPERABLE CONTROLS LOCATED ON qb-A-B TWO REELS (FREE AIR EN ERIN PIPING BEFORE <br /> ® FREE STANDING PEDESTAL 15 54" 1 COMPRESSOR) A5 MF6 BY DURO ENTERING MANHOLE. <br /> 12g0. STEEL 15LAN12 FORM BY AMFAB -- FOR A 10" MAX. REACH DEPTH. EXTREME COLD WEATHER SITES <br /> •200-KD OR PRE-APPROVED EQUAL, t CAL. t DISPENSER H05E 4 NO H2O MODEL 9T-A-S, <br /> PAINT VERTICAL SIDES,SHERY41N I'-0" ONLY 6A50LINE HOSES SHALL BE COLD AREAS W/ H2O, ADD HTR. N <br /> 5'-0° 4'-6" - 6" ROUND STEEL <br /> WILLIAMS 5TRUC.TURAL GRAY. sde""r e.m LONG/ RETRACTABLE. gg_q_B_ <br /> +a.M, NOTE: LONG/RETRACTABLE HOSE POST(TYP) REVISIONS <br /> 12" 5Q. COLUMN f em tou"m�e <br /> b" R 1'-6" R DISPENSER CONFIGURATION IS NOT APPROVED <br /> O NOZZLE FOR USE WITH BALANCE SYSTEMS Q �v15m F�FlFE <br /> " AIR d WATER DEPT.COMMENTS <br /> DISPENSER (PH II) IN JURISDICTIONS GOVERNED 1041/05 <br /> AFEWA 1�;.,`,\ % 1 BY GARB. BA UNIT STL. BRAD BASE PLAN WITH WINDOW WASH RAN 6HT BULKHEAD FOR <br /> t HOSE,WATER BIBS <br /> LOW DECAL __z <br /> TRAS <br /> FE"T 02/20/04 <br /> EXPANSION JT. frrnJ B SERVICE,DCI MARKETING, FLEXIBLE CONDUIT FOR <br /> ISOLATION JOINT _ PART#YONSOCZ61R IT L16HT POWER <br /> DISPENSER BASE g ! `Q �, ,� 1 j 4"x4" J-BOX <br /> 5/8'x14° LONG ANCHOR BOLT5 (6) ! 1" CONDUIT FROM WIREWAY <br /> COLUMN CLADDING,SEE CAI DURO 418-A-B URO MANUFACTURING '10 68'1-8866 m ! FLEXIBLE CONDUIT FOR <br /> W/MAXIMUM II" THREAD ABOVE <br /> DRESSER WAYNE MULTI-PRODUCT I - SENTRY AIR/WA7ER W/COMPRESSOR, LIGHT TOWER <br /> FUEL DI5PEN5ER 12 WIRE BRAIDED HOSES AND "AIR/WATER" 516N ON POLE I FINISHED CONCRETE <br /> GUAROPOST5 - DURO 5 CURB - " EYS 55EA R _ <br /> OPTION #2 -NON-ELECTRIC SIGN OPTION :k.z�, : = - - SUBMITTAL <br /> SPECIAL EQUIP.DISPENSER ISLAND PLAN /� DISPENSER ELEVATION EVC1 MARKETING (414)228'-10007 Z6R PAVEMENT p F E DATES <br /> 1/4"=1'-0" (�} I/2"=I'-0" - PCI WA5TE/WIN5HIELD SERVICE CENTER W/5OUEEGEE - WHITE II- #4 ® 12" OC. OWNER: <br /> �� 1. BOTH WAYS T d B <br /> ELEVATION rt l-0 RE6. AGENCIES SUBMITTAL <br /> 12"m MANHOLE (PJC OR STEEL) W/COVER : 09/08/03 <br /> 6'-6" INSTALL AIR/WATER PIPING BELOW FREEZE <br /> 12" x 18" DEEP MANHOLE LINE. INSTALL AN ISOLATION BLOCK 4 BLEED PEA GRAVEL OUT TO BID: 10/17/03 <br /> OR <br /> SECOND R FIXTURE MTD. 90° 15" W/COVER TO PROVIDE ACCESS VALVE BEAVER 400-12RL BACKFILL <br /> CGGURSRS 180o FROM FIRST WHERE. SEE SITE PLAN I/2WATO 5HUT-OFF/BLEED VALVES <br /> " TER—� <br /> I-- 400 W METAL HALIDE SUPPLY LINE 5'NB-UP FOR WATER SECTION A 8 <br /> I LUMINAIRE WITH 5" 50. POLE 0 <br /> 4 I AND BRACKET ASSEMBLY 'S CONNECTION on <br /> 221/4" <br /> ALI6N FACE OF LUMINAIRE 4 ELECT. CONNECTION QUICK COUPLER VALVE w O <br /> W/CURB FACE _ STUB-UP FOR ELECT. <br /> FOOTING LEGEND - BASED ON IdAl U.B.C. 80 = LOCKING GAP, RAIN z <br /> Vi/ a 5Y <br /> HO MPH, EXPOSURE G Q BI r b" GUARD P057(T"CP. 2) BIRD , 33 DRC S W � <br /> - <br /> x H D B MAX. MOMENT j m w,a <br /> O' TO 15, 3' I'm 895 - -- X FINISH GRADE z �' <br /> TO L16H FOR POWER VALVE BOX GHRISTY , F o <br /> IS'-I" TO 20' 4' 2'm 1657 TO LIGHT d COMPRESSOR w <br /> Q e TRASH CAN WITH WINDOW WASH $ BB2424-61G, EXTENSION <br /> IO O z 56 <br /> (6) >P3 TIES - _ EQUAL <br /> L 12 EXTENSION OR w M <br /> 20'-1" TO 25' s' 2'-6°m 228"1 - - <br /> ® 3 Ob. 25'-1" TO 50' 5' 2'-6'm 2690 SERVICE, DGI MARKETING, EQUAL <br /> 5 <br /> PART#WV:FiCRCZGR #4 REBAR STAKE W/(2)CLAMPS rj <br /> W O � <br /> m AL16N WITH TOP OF CURB ALIGN (N) AIR/ 48" HIGH MINIMUM <br /> YARD SURFACEb" CURB 8" WATER W/(FJ 6" 3/4" WATTS 600 SERIES U W <br /> -- . r a <br /> -' / '-2" I/2" " e° 2'-5 1/ CURB �_ GHEGK VALVE. (7YP 2) 6 <br /> NAT. 'T 7 fi__: T-' CONCRETE FOOTING W/ N07E; <br /> 6RADE I T 1 SLOPED TOP 4 TOOLED EDGES GALVANIZED NIPPLE <br /> O I I I 1 (6) #3 TIES ® 3" O.G. 1 PLAN ALL EXPOSED =+ <br /> `I l___'1' WATER PIPING I G.F. PEA GRAVEL p <br /> - z I I GALVANIZED ELLS <br /> #i EI 1 (4) #4 VERTICAL BARS `s„ PIPING <br /> 16" O.G. 12" GALVANIZED NIPPLE <br /> WRAP AROUND TIES <br /> 3" <br /> 012,10.0. <br /> -°- 3/4" 6ALVANIZED MAINLINE <br /> #3 <br /> SIDE VIEW <br /> (TYPJ L51 STM-4-400-5W-F <br /> PROJECT NO <br /> B -MT-BLK STARBEAM 400 WATT BLACK FIXTURE W/ BRKT n 10.5&40 <br /> _... <br /> L51 55050-5016-20 �. <br /> - �� - ---_- -- -- -- ��--- 3" 6ALVANIZED NIPPLE DRAWN BY: <br /> -STEEL 50. POLE 5" x 20' 2-BOLT PATTERN BLK <br /> LSI seG (122561) <br /> GALVANIZED ELL CHECKED BY. <br /> - <br /> 5' 50. BASE COVER 1 , 3/4" GALVANIZED NIPPLE <br /> OAP 5AVED NAME: <br /> E 6 L _ i 2 IO fF55.dw <br /> 6 Y cl'-O"H7 DETAIL 5 NOT TO 50ALE 8 12 - / WATER DETAILE TOP VIEW VALVE BOX <br /> V <br /> n -- - --- - -- - - - o <br /> n N Z o <br /> 1/4" DEEP PETROLEUM 1/4" DEEP PETROLEUM .... # O Ul <br /> E 1/4" R TOOLED RESISTANT SEALANT BURKE 00 O Q <br /> RESISTANT SEALANT UAL <br /> USEAL #3204 OR EQUAL U-SEAL #3204 OR EQUAL EDGE JOINT 1-I/2° OR I/4" W � O O <br /> _o Irl" TOOLED TO 1/44 RADIUS IF i/4 SLAB TOOLED TO 1/4" RADIUS Q O O <br /> d 51DEKALK OR PLASTIC INSERT 15 NOT USED DEPTH O V ® O <br /> EARTH AT FILL PIPE WITH F O <br /> o PLANTER b„ BALKER ROD PER CONCRETE - DOME (/� Z O O p, <br /> BACKER ROD PER O O Z o- <br /> MANJFACTURERS SPECS — — — — — } # to <br /> I/2" R MANUFACTURERS SPECS <br /> TYP. N 3^ 1/2"m X 18" OILED SMOOTH 10 <br /> v _ STEEL DOWEL a 18" O.G. REINFORCING CONTINUES 4" REFLECTIVE DECAL <br /> Cqy <br /> n _ ACRO55 JOINT(AS OCCUR5) <br /> - -ASPHALT INTERFIUPT REINFORCINS AT :Q b"m STEEL PIPE W O mi <br /> a o - PAVING JOINT (A5 APPLICABLE) TOOLED CONTROL DONT m Q SCH. 10 FTG. Ly„ H O <br /> " m PAINT WHITE-PITTvBURG PAINT <br /> 6 E JOINT FILLER (OR SAWGUT) #8355 Q <br /> AC. PAVING OR N <br /> CONCRETE SLAB <br /> .� A CONT. TOP EXPANSION JOINT @NEW `STAB 1/4" DEEP PETROLEUM -4 <br /> i AND BOTTOM <br /> I A I/2" RESISTANT SEALANT I/4„ #3204 OR APPROVED EQUAL � I <br /> TOOLED TO 1/4" RADIUS IF BACKER ROD PER ; - a SHEET TITLE <br /> 1PLA�G��T MANUFAGTURER5 MIS`C. <br /> €.� GONG. CURB --�_ a,� e m RECOMMENDATION S1 _ EXPANSION JOINT SITE <br /> BACKER ROD PER q — — i — — EAE, LaJOINT BY m GONGREtE FOOTING DETAILS <br /> m 'Uhi MAMJFAG'NF2ER5 SPECS Uj OR <br /> APPROVED EQUAL <br /> JOINT FILLER <br /> NOTES: REINFORCING CONTINUES <br /> ACROSS JOINT - <br /> 1. PROVIDE CONSTRUCTION JOINT5 ® 25' O.G. MAX. AND <br /> 0 A7 CURVES, TANGENTS, AND CORNERS. INTERRUPT REINFORCING AT (� <br /> 4 - 2. BASE OF CURB TO REST ON COMPACTED FILL WITH A JOINT(A5 APPLICABLE) STEEL STAKES AT COLD l <br /> z KEYED JOINT DURIN6 POUR <br /> F < MINIMUM DEPTH OF 16" AT STOREFRONT SIDEWALK AND <br /> G a 12" AT ALL OTHER LOCATIONS. THICKENED SLAB WHERE <br /> 0 3. SACK FINISH EXPOSED SURFACES. OCCURS, SEE THICKENED D NOTE: SHEET NO. <br /> Q- 4. RUN 5AR5 CONTINUOUS THRU CONSTRUCTION JOINT5. �1 ISOLATION JON' SLAB EDGE NOTE; FOR INTERRUPTED POURS, SUBMIT FROF05M <br /> o SUBSTITUTED FOR CONTROL JOINT ALTERNATE TO ENGINEER <br /> d d` FOR APPROVAL <br /> FS5 <br /> 3 CURB DETAIL EXPANSION JOINT n GUARD POST <br /> 11/2"-1'-0" 5/4"=1'-O" G I/2"=I'-0" J <br />