Laserfiche WebLink
t <br />�ND <br /> J <br /> ALLI d1olm;0 1: 3r L A It C ii I 'IE C 'r U It P, • li N ti I N P. P. It I N I; I'. N V I R 0 N N1 I N I A I S I': R V I t f <br /> GROUP INC. 1340 Arpiold Drive, ,Settle. 110, A1arNnez, CA 9455.3 Mephoue: (915) 3/.3-9700 Fammilr: (915) <br /> John W.Johnson <br /> Co-President <br /> Architect <br /> October 16,2003 w <br /> Brian F. Zita CD <br />_ Co-President Ms. Michelle Le C-') <br /> Architect San Joaquin County <br /> Environmental Health Department J <br /> 304 East Weber Avenue, Third Floor <br /> John B. Hicks Stockton, CA 95202 <br /> Vice presidentcn <br /> cn <br /> Cecil R. Spencer RE: Safeway Fueling Center#2707 <br /> Vice president 6425 N.Pacific Avenue <br /> Stockton, California <br /> Plan Check#1 Response <br /> Regional Managers <br /> Jesse E. Macias Dear Ms.Le: <br /> Roy W. Pedro This letter is in response to your plan check review comments#1,dated September 29,2003 <br /> Alan IC Shimabukuro for the Safeway kiosk/Gas Station submitted for application to install underground storage <br /> John W. Strobel tanks at the above referenced location.Our responses to the review comments are listed <br /> Blythe R.Wilson below and attempt to follow the same order of appearance as your review documents. <br /> 1. A balance in the amount of$135.00 dollars is due. The fee received by this office paid <br /> for the installation of 2 underground storage tanks but 1 tank is split into 2 <br /> compartments therefore;:3 UST's are being proposed. <br /> A check in the amount of$135.00 is attacher[. <br /> 2. Buoyancy calculations signed by a professional engineer or licensed architect must be <br /> submitted. <br /> Two (2) copies of the tank buoyancy calculations signed by a licensed engineer <br /> are attached <br /> 3. Page FS3-drawing 4 shows a connector tube being used to link the piping through the <br />'ER'S dispenser pans. Secondary termination must occur within the dispenser pan. Clarify <br /> Offices drawing. <br /> NG <br /> p.) BELLEVUE, WA The connector tube is located inside the dispenser sump. Any product leakage <br /> LA HABRA, CA within the tube will be secondarily contained within the dispenser sump. <br /> MARTINEZ, CA <br /> 4. The permit application specifies that overfill prevention will be satisfied using CCR <br /> PETALUMA, CA 2365(b)(2)(B). However,manufactures specification sheets were not submitted for an <br /> SACRAMENTO, CA external audible/visual alarm and the location of this alarm was not implicated on the <br /> drawings. <br />— SCOTTS DALE, AZ <br /> VANCOUVER, WA <br /> vanucrhidesign.com <br />