LINE LEAK LOCKOUT SETUP <br /> PLLD LINE DISABLE SETUP <br /> LOCKOUT SCHEDULE 10:91-DIESEL ANNULAR - - - - - - - - - - - - <br /> DAILY LRI-STATE (SINGLE FLOAT) <br /> START TIME: DISABLED CATEGORY : ANNULAR SPACE Q 1 :87 <br /> STOP TIME DISABLED <br /> ' IN-TANK ALARMS <br /> T 1 :HIGH WATER ALARM <br /> 1_11 :87 STP SUMP T 1 :INVALID FUEL LEVEL <br /> TRI-STATE (SINGLE FLOAT) LIQUID SENSOR ALMS <br /> : STP SUMP L I :FUEL ALARM <br /> L 2:FUEL ALARM <br /> L12:91 STP SUMP L 3:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 4:FUEL ALARM <br /> CATEGORY : STP SUMP L 5:FUEL ALARM <br /> L 6:FUEL ALARM <br /> L 7:FUEL ALARM <br /> LIQUID SENSOR SETUP L13:DIESEL STP SUMP L 8:FUEL ALARM <br /> - - - - - - - - - - TRI-STATE (SINGLE FLOAT) L11 :FUEL ALARM <br /> CATEGORY : STP SUMP L 1 :SENSOR OUT ALARM <br /> L I :DISP 1-2 L 2:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 3:SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN L14:87 FILL SUMP L 4:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 5:SENSOR OUT ALARM <br /> CATEGORY : OTHER SENSORS L 6:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> L '-,:DISP 3-4 L 8:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) 1_15:91 FILL SUMP L11 :SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN TRI-STATE tSINGLE FLOAT) L I :SHORT ALARM <br /> CATEGORY : OTHER SENSORS L 2:SHORT ALARM <br /> L 3:SHORT ALARM <br /> L 4:SHORT ALARM <br /> L 3:DISP 5-6 L 5:SHORT ALARM <br /> TRI--STATE (SINGLE FLOAT) L16:DIESEL FILL SUMP L 6:SHORT ALARM <br /> CATEGORY : DISPENSER PAN TRI-STATE (SINGLE FLOAT) L 7:SHORT ALARM <br /> CATEGORY : OTHER SENSORS Lll :SHORT ALARM <br /> PRESSURE LINE LEAK <br /> L 4:DISP 7-8 Q 1 :PLLD OPEN ALARM <br /> TRI-STATE (SINGLE FLOAT) L17:VENT SUMP Q I :CONT HANDLE ALM <br /> CATEGORY : DISPENSER PAN TRI-STATE (SINGLE FLOAT) <br /> CATEGORY OTHER SENSORS ISD SITE ALARMS <br /> [SD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> L 5:DISP 9-10 ISD VAPOR LEA}: FAIL <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN ISD VP PRES FOL <br /> ISD VP STATUS FAIL <br /> ISD SETUP FAIL <br /> ISD SENSOR OUT FAIL <br /> L 6:DISP 11-12 <br /> TRI-STATE (SINGLE FLOAT) ISD HOSE ALARMS <br /> CA!'EGORY : DISPENSER PAN ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> ALL:FLOW COLLECT FAIL <br /> L 7:D1 ',P 13-14 OUTPUT RELAY SETUP Q 2:87 <br /> TRI-STATE (SINGLE FLOAT) IN-TAN}: ALARMS <br /> : DISPENSER PAP! R 1 :OVERFILL <br /> T 1 :HIGH WATER ALARM <br /> TYPE: T I :INVALID FUEL LEVEL <br /> STANDARD <br /> NORMALLY OPEN LIQUID SENIOR ALMS <br /> LB:D.ISP 15-16 L I :FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) TANK 0: NONE L 2:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L 3:FUEL ALARM <br /> fJ-TANK ALARMS L 4:FUEL ALARM <br /> I <br /> ALL:OVERFILL ALARM L 5:FALARM <br /> L 9:87 ANNULAR ALL:HIGH PRODUCT ALARM L 6:FUEL EL ALARM <br /> TRI -STATE (SINGI FLOAT) ALL:MAX PRODUCT ALARM L 7:FEL ALARM <br /> CATEGORY : ANNULAR SPACE L B:FUEL ALARM <br /> L11 :FUEL ALARM <br /> L I :SENSOR OUT ALARM <br /> L 2:SENSOR OUT ALARM <br /> L 3:SENSOR OUT ALARM <br /> L 4:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALAR'I <br /> L 6:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br />