Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> 600 East Main Street Donna Heran, REHS <br /> W Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> 94/FpR�\ Website: www.sjgov.org/ehd Kasey Foley, REHS <br /> June 28, 2010 Phone: (209) 468-3420 <br /> Fax: (209) 464-0138 <br /> Marty Weithman <br /> Service Station Systems, Inc. <br /> 680 Quinn Ave <br /> San Jose, CA 95112 <br /> Re: Safeway, Inc., 6425 N Pacific Ave, Stockton, CA SR0060288 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to replace the vent sump liquid sensor and line leak detectors on the <br /> 87-2 and diesel lines on the underground storage tank (UST) system at the above noted <br /> address. The vent sump sensor was installed and tested by Service Station Systems and <br /> witnessed by EHD on June 16, 2010. The permit has been approved with the following <br /> conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Garrett Backus at (209)468-2986 to arrange the following inspection <br /> appointments (a 48-hour notice is required for inspection appointments). Please be <br /> aware that inspections for emergency work must be scheduled within five days of permit <br /> approval. <br /> a. Leak detector test: Leak detector must be tested to confirm that the device can <br /> detect a leak of 3 gallons per hour at 10 psi. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br /> c. A valid, current certificate of training from the manufacturer(s)of the component(s) <br /> being tested, repaired, or serviced. <br /> 5. Qualified installers must possess or work under the direct and personal supervision of an <br /> individual physically present at the work site who possesses all of the following: <br />