Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> (17- /6- oto <br /> VIO <br /> ONS <br /> # Code Section HSC=CA Health&SafetyCode;CCR=CAC de of ViRe Regulations;V= olation; RV=Re eat Violation V V <br /> Designated operator monthly inspection: (c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (d), UDCs,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted- (c)(6) <br /> (e) employee training not verified;(d)(e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1) not performed; (2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair,replacement,calibration, or certification; (f) performed, and failed to affix a tag/sticker on each <br /> monitoring equipment com onent that was certified, repaired, or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed (M1) <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present Mt <br /> 28 CCR 2661 Repair for tank or piping not tested for tightness within 30 days of completion of the repair (Mz <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed(pre-January 1, 1984 M1 <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984 (Mt) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 26299(a)(9) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636 6 Emer enc enerator monitoring system not checked daily or to not kept (Mt) <br /> 41 HSC 25281.5 b 3 Unburied fuel piping not visual) inspected at least month) or to not kept <br /> Mt) <br /> VPH Systems HSC 25290.2 installed between 07/01/03 and 06/30/04 HSC 25290.1 (installed on or after 07/01/04 <br /> Compatibility and permeability requirements: (a) UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored; (b) results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2 c 2 <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2 c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the <br /> HSC 25290.2 d entryof liquid or vapor from the rima containment into the seconds containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space <br /> of the UST system not maintained <br /> 1Q) UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) <br /> HSC 25290. <br /> 48 HSC 25290.10) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 OtheD See attached"Continuation-Official Inspection Report"forviolation(s)not listed above. <br /> EHD Inspector: ^-,"!5 Phone: �Z .oq-) UIC <br /> Septic system: <br /> —7,q U Serves 20 people/day <br /> Recei d ride: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> ❑Dry wells/French Drains <br /> EHD 23-02-002 REV 04/08/10 Page 2 UST OFFICIAL INSPECTION REPORT <br />