My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:02:33 PM
Creation date
5/15/2019 2:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File MH29667 Page T1-2 of 2 Issued: 2005-09-08 <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />METHOD <br />One sample assembly as described in Item B was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min. while the samples were examined for evidence of leakage. <br />loot Methanol <br />50t Methanol/50% ASTM Reference Fuel C <br />15% Ethanol/858 ASTM Reference Fuel C <br />lot Ethanol/901 ASTM Reference Fuel C <br />151 MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />METHOD <br />One sample assembly as described in Item C was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluids <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a period <br />of at least 5 min, while the samples were examined for evidence of leakage. <br />100% Methanol <br />50% Methanol/50% ASTM Reference Fuel C <br />loot Ethanol <br />50% Ethanol/50% ASTM Reference Fuel C <br />15t Ethanol/85t ASTM Reference Fuel C <br />lot Ethanol/90t ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />
The URL can be used to link to this page
Your browser does not support the video tag.