My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:02:33 PM
Creation date
5/15/2019 2:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONTACT' FOR MORE INFORMATION! <br />5555 Skylone Blvd., St , A / Santa Rosa, CA 95403 <br />Ph: (800) 688-3375 / Fx: (800) 700.1188 <br />www.westemfg.com <br />may be tested to a minimum of 15" and a maximum of full vacuum at <br />29.95'. Always follow all local regulations and restrictions. <br />PLEASE NOTE: U. L. Listed DMA sumps require a listed, approved, electronic <br />monitor/alarm system to be installed for operator notification in the event <br />of product leakage into sump area. <br />ADDITIONAL TESTING REQUIREMENTS - STATE OF FLORIDA ONLY: <br />Leak Test Requirement: <br />1) a. Fill entire sump within 4 to b inches of top. <br />b. Observe water level for a minimum of 3 hours. <br />c. Water level shall not decrease more than allowable for <br />normal evaporation. <br />2) a. Fill interstitial space of sump within 4 to b inches of top. <br />b. Observe water level. <br />c. Water level shall not decrease more than allowable for <br />normal evaporation. <br />Interstitial space shall be tested by vacuum (5 bars) or pressure (2 psi) for a <br />minimum of 10 minutes. <br />MAINTENANCE AND INSPECTION: <br />Fiberglass containment sumps require periodic inspections to check for <br />damage that can occur during operation or from natural causes. Any <br />shatters, tears or cracks must to be repaired so as to bring the damaged <br />area equal in strength to the original section. Any above ground exposure <br />must be covered by UV protection either in original construction or with <br />gel coats or pigments. <br />Poly -Composite containment sumps require periodic inspections to check <br />for damage that may occur either in operation or from natural causes. <br />Any shatters, tears or cracks cannot be repaired as in fiberglass <br />containment sumps. Poly -Composite containment sumps have no UV <br />protection and are for below ground use only. <br />Periodically inspect the DMA base mounting and safety/impact valve <br />anchor bracket systems. Check these for tightness and any visual <br />damage, cracks or corrosion. <br />Containment sumps and their bracket, seal and mounting anchors can <br />be inspected during the normal maintenance and service procedures <br />done on the dispenser filters, submersible pumps and other equipment <br />Page 25 of 38 <br />
The URL can be used to link to this page
Your browser does not support the video tag.