My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:02:33 PM
Creation date
5/15/2019 2:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UPCF UST -D (12/2007) 314 <br />UNIFIED PROGRAM CONSOLIDATED FOR'" <br />• UNDERGROUND STORAGE TANK <br />MONITORING PLAN (Page 2 of 2) <br />VI. UNDER DISPENSER CONTAINMENT (UDC) MONITORING <br />1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD <br />490.54a <br />49a54b <br />X 1. CONTINUOUS ELECTRONIC MONITORING 112. FLOAT AND CHAIN ASSEMBLY ❑ 3. ELECTRONIC STAND-ALONE <br />❑ 4. NO DISPENSERS ❑ 99. OTHER (S i ): <br />PANEL MANUFACTURER: Veeder Rost TLS350-R °9°-55 MODEL#: 848290-012 <br />49 56. <br />LEAK SENSOR MANUFACTURER: Veeder Root 490-57 1 MODEL #(S): 794380-208 <br />490-58 <br />DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ® a. YES ❑ b. NO <br />490-59 <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ® a. YES ❑ b. NO <br />49060. <br />FAILURE / DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a. YES ❑ b. NO <br />490-61 <br />UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER ® a. YES ❑ b. NO <br />49x62 <br />2. UDC CONSTRUCTION IS X 1. SINGLE-WALLED 0 2. DOUBLE-WALLED <br />49°63 <br />IF DOUBLE WALLED: <br />490.6H <br />UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ 1. LIQUID [12. PRESSURE ❑ 3. VACUUM <br />A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ®a. YES ❑ b. NO <br />490-64b <br />VII. PERIODIC SYSTEM TESTING <br />1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br />4� <br />LEAK DETECTION MLM MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR 2644.1 <br />® 2. SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br />49046 <br />3. SPELL BUCKETS ARE TESTED ANNUALLY. <br />490-67 <br />VIII. RECORDKEEPING <br />The following monitoring1maintenance records are kept for this facility: <br />®Alarm logs 49mea ❑ Visual Inspection Records 490-6eb ❑ Tank integrity testing results 49o-6ac <br />❑ SIR testing results (and supporting documentation records). 49asm ❑ Tank gauging results (and supporting documentation records). 49mSe <br />® ATG Testing results (and supporting documentation records). 49o-6ef ❑ Corrosion Protection 60-day logs 490-6ee <br />® Equipment maintenance and calibration records. 490.68h <br />DL TRAINING <br />® Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties. 490690 <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) <br />® THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) 49049b <br />® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) 49Mk <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490.69d <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49P6% <br />❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION' 490.69f <br />❑ SWRCB PUBLICATION: 'UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS- 490-as <br />❑ OTHER (Specify): M69h, ta69i <br />This facility has a "Designated USE Operator" who has passed the California UST System Operator Exam administered by the International Code Council (ICC). <br />The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the USE systems annually, and within 30 days of hire. This <br />training will include, but is not limited to, the following <br />D Operation of the UST systems in a manner consistent with the facility's best management practices <br />➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br />D The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br />D Names of contact person(s) for emergencies and monitoring alarms. 49o-7o <br />X. COMMENTS/ADDITIONAL INFORMATION <br />Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490-71 <br />XI. PERSONNEL RESPONSIBILITIES <br />The USE Owner/Operator is responsible for ensuring that: 1) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br />this planoccurs, 2) all conditions that indicate a possible release are investigated, and 3) all monitoring records are maintained properly. <br />The following person(s) are responsible for performing the monitoring and equipment maintenance: <br />NAME Aldo Basurto 490-n TITLE Fuel Operations <br />490-73 <br />NAME Stan Olea 49074 TITLE Fuel Operations Manager <br />49x75 <br />The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator <br />of any <br />conditions that need follow-up action. <br />XII. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />APPLICANT;zI("i,NATURE 09076 <br />DATE: <br />a90n <br />(F)"'J/, L/ <br />June 4, 2009 <br />.T k /Qaemtor 0 2 Facilit ncr/ ray r l A h R <br />APPLICANT NAME (print): 49078 <br />APPLICANT TITLE: <br />490.79 <br />Butch Hobson <br />Safety and Environmental Affairs Manager <br />UPCF UST -D (12/2007) 314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.