Monitoring System Equipment Certification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited: Chapter 6.7, Health and Safely Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: Safeway 2707 Bldg.No.: <br /> Site Address: 6425 N.Pacific Ave. City: Stockton,CA Zip: 95207- <br /> Facility Contact Person: Manager Contact Phone No.: (209)472-8600 <br /> Make/Model of Monitoring System: VIR TLS-350 Date of Testing/Servicing: 6116110 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID•01-Regu Tank ID: 02-Prem <br /> 1% In-Tank Gauging Probe. Model: VR u7390-109 ()j In-Tank Gauging Probe. Model: VR 8.,17390-109 <br /> IN Annular Space or Vault Sensor. Model: VR 79,1390460 IN Annular Space or Vault Sensor. Model: VR 794390460 <br /> IN Piping Sump\Trench Sensor(s). Model: VR794390-209 IE Piping Sump\Trench Sensor(s). Model: VR 79,1380-208 <br /> CS Fill Sump Sensor(s). Model: VR 79,1380-208 (i( Fill Sump Sensor(s). Model: VR 794MO-208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> (3 Electronic Line Leak Detector, Model: VR Sade.8484 13 Electronic Line Leak Detector, Model: VR sedes 8494 <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 03-Diesel Tank ID: <br /> In-Tank Gauging Probe. Model: VR 847390-109 ❑ In-Tank Gauging Probe. Model: <br /> t% Annular Space or Vault Sensor. Model: VR794390460 ❑ Annular Space or Vault Sensor. Model: <br /> (% Piping Sump\Trench Sensor(s). Model: VR 794390-208 ❑ Piping Sump\Trench Sensor(s). Model: <br /> fg Fill Sump Sensor(s). Model: VR 794380.209 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Va sada•9ae4 ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 01-02 Dispenser ID: 03.04 <br /> Ig Dispenser Containment Sensor(a). Model: VR79t390-209 2 Dispenser Containment Sensor(s). Model: VR79438a-208 <br /> gj Shear Valve(s). IN Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 05A6 Dispenser ID: 07-08 <br /> pj Dispenser Containment Sensor(s). Model: VR 79,180.208 IN Dispenser Containment Sensor(a). Model: VR 796380.208 <br /> fE Shear Valve(s). 13 Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID; 09.10 Dispenser IDI 11-12 <br /> 13 Dispenser Containment Sensor(a). Model: VR 79A99-209 la Dispenser Containment Sensor(s). Model: VR 794MG-208 <br /> Shear Valve(s). [3 ShearValve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> -If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is eorrest and a Not Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (check all that apply): ❑ System set-up ❑ Alarm history report <br /> Technician Name(print): Randy Wilkerson Signature: // tlr- <br /> Mfg.Cert.#.: A32404 ICC# 5258560-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems PhoneNo.: (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave.,San Jose, CA 95112 Date of Testing/Servicing: 6/16/10 <br />