My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
2402
>
2200 - Hazardous Waste Program
>
PR0513703
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 9:32:54 AM
Creation date
5/16/2019 9:30:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513703
PE
2220
FACILITY_ID
FA0009213
FACILITY_NAME
WHITE ARROW INC
STREET_NUMBER
2402
Direction
S
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95206-3220
CURRENT_STATUS
01
SITE_LOCATION
2402 S CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAU I N Environmental Health Department <br /> Qb' <br /> —COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: T2402 <br /> acility Address: Date: <br /> WHITE ARROW INC S CALIFORNIA ST, STOCKTON May 14, 2019 <br /> Treatment,Transport and Disposal <br /> 206 HSC 25160.2(c)(2) Waste stream or generator not eligible to use consolidated manifesting procedure o V n R o COS <br /> 207 HSC 25144.6(b) Failure to properly manage reusable soiled textile materials c V o R o COS <br /> 208 HSC 25200.3.1(c) Failure of laboratory to comply with hazardous waste treatment requirements o V o R o COS <br /> 209 CCR 66262.34(d)(2) Failure to remove all hazardous waste from tanks,containers and containment upon facility closure o V o R o COS <br /> Preparedness and Prevention <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste o V o R o COS <br /> 302 CCR 66262.34(d)(2) Failed to maintain required emergency equipment o V o R o COS <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems,spill control,or decontamination equipment ■V o R o COS <br /> 304 CCR 66262.34(d)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies o V o R a COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition o V n R n COS <br /> 402 CCR 66262.34(d)(2) Failed to store hazardous waste in a compatible container o V ❑R o COS <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste o V o R o COS <br /> 404 CCR 66262.34(d)(2) Failed to inspect hazardous waste storage areas at least weekly o V n R n COS <br /> 405 CCR 66262.34(d)(2) Failed to manage incompatible wastes in containers properly n V n R o COS <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied ■V o R o COS <br /> 407 CCR 66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator o V :)R o COS <br /> 408 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste stream o V n R o COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank o V ❑R o COS <br /> 502 CCR 66262.34(d)(2) Tank system inspections of discharge systems,monitoring equipment,and tank levels not done daily o V o R o COS <br /> 503 CCR 66262.34(d)(2) Tank system inspections of construction materials,fixtures,and surrounding areas not done weekly n V o R o COS <br /> 504 CCR 66262.34(d)(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment o V ❑R o COS <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks o V o R o COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days o V o R ❑COS <br /> 602 CCR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longer than one year or 180 days after fill date o V o R c COS <br /> 603 CCR 66262.34(e)(1)(C) Failed to mark initial accumulation start date on satellite containers o V ❑R o COS <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days o V o R c COS <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste o V o R o COS <br /> 606 CCR 66266,81(a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption n V o R o COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not properly managed and labeled o V ❑R ❑COS <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel fillers ■V o R o COS <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials ❑V o R c COS <br /> FA0009213 PRO513703 SCO01 05/14/2019 <br /> EHD 22-01 Rev.09/27/2018 Page 2 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.