My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1419
>
3500 - Local Oversight Program
>
PR0544465
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 2:26:46 PM
Creation date
5/16/2019 11:29:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544465
PE
3528
FACILITY_ID
FA0005837
FACILITY_NAME
STEFANOS GASOLINE*
STREET_NUMBER
1419
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137016
CURRENT_STATUS
02
SITE_LOCATION
1419 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ai <br /> 4 <br /> + Former Stefano's Gasoline Station Page 2 <br /> 1419 East Charter Way February 2, 2012 . <br /> Stockton, California 95205 <br /> As stated in the letter dated 14 .October 2011 to the CUF, it is the opinion of the EHD that <br /> remediation of the secondary source of impacted groundwater through continued ozone <br /> injection using a reinstalled OZ-4-is still practicable; however, -in view of the decision by the <br /> CUF (issued by email dated 31 January 2012) thatthe "limited area of soil contamination and <br /> the direction of groundwater gradient was unlikely to create a vapor threat" and that the site <br /> should be closed, the EHD will not direct tt at OZ-4 be destroyed and new ozone injection <br /> points be installed. Instead,' the EHD will work to close this site since the CUF. has <br /> recommended site closure and there are limited reimbursements of expenses allotted to sites <br /> that have been recommended for closure consideration by the CUF; and the EHD also notes <br /> that the impacted,groundwater�has been reasonably delineated. <br /> To this end, the EHD directs that a closure summary report be submitted to the EHD by 15 <br /> May 2012 that: <br /> • Provides an estimate when groundwater will return to water quality goals; <br /> • Includes Table. 1 - Checklist of Required Data for .No Further Action Requests at <br /> Underground Tank Sites (Appendix A — .Reports, Tri-Regional Board Staff <br /> Recommendations for Preliminary Investigation and Evaluation of Underground Tank <br /> Sites, dated` 16 April 2004, published `by the California. Environmental Protection <br /> Agency Regional Water Quality Control Board Central Valley Region; <br /> • Provides a declining trend analysis; <br /> • Addresses the human health risk and hazard posed to residents of the motel located <br /> approximately twenty feet from monitoring well MW-2 where high concentrations of <br /> contaminants of concern were detected; and <br /> • Provides calculations showing current estimates .of the residual dissolved and <br /> adsorbed contaminant masses of.total petroleum hydrocarbons as gasoline following <br /> remediation by injection of ozone between March and September 2011. <br /> The EHD directs .that all monitoring and sampling at this site be suspended while the site is <br /> being considered for closure. If you have any .questions, please contact Vicki McCartney at <br /> (209) 468-9852 or by e-mail at vmccartney@sjcehd.com. <br /> Sincerely, - <br /> Victoria L. McCartney, REHS Nuel C. Henderson,'Jr., PG <br /> Senior Registered Environmental Health Specialist Engineering Geologist <br /> i <br /> C, Mr. Brian W. Millman, PG, Advanced GeoEnvironmental, Inc., 837 Shaw Road, Stockton, <br /> California 95215 <br /> Mr. James L.L. Barton, PG,, California Regional Water Quality Control Board Central <br /> I Valley Region, 11020 Sun Center Drive, Suite 200, Rancho Cordova, California 95670 <br /> 1 <br /> 4 <br /> 14 <br /> Y <br />
The URL can be used to link to this page
Your browser does not support the video tag.