My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001528
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1419
>
3500 - Local Oversight Program
>
PR0544465
>
ARCHIVED REPORTS XR0001528
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 1:45:03 PM
Creation date
5/16/2019 1:14:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001528
RECORD_ID
PR0544465
PE
3528
FACILITY_ID
FA0005837
FACILITY_NAME
STEFANOS GASOLINE*
STREET_NUMBER
1419
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137016
CURRENT_STATUS
02
SITE_LOCATION
1419 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- r <br /> v <br /> ' 14 November 2005 <br /> AGE-NC Project No 03-1100 <br />' Page 3 of 4 <br /> v <br /> The ground water flow direction was inferred to be flowing towards the southeast in the former UST <br />' location at a calculated hydraulic'gradient of 0 006 foot per foot (ft/ft) Figure 3 illustrates the <br /> contoured ground water elevations as measured on 02 September 2005 <br /> r <br /> 12 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> 1 TPH-g was detected in the ground water sample collected from well MW-2 at a concentration of <br /> 210,000 micrograms per liter (µg/1) BTEX compounds were detected in the ground water sample <br />' collected from well MW-2 at a concentration of 2,800 µg/1 (benzene), 16,000 µg/l (toluene), <br /> 4,000 µg/l (ethylbenzene), and 24,200 µg/l (total xylenes) <br />' -1,2-DCA was detected-in ground water samples collected from wells MW-2 and MW-3 at <br /> concentrations of 19 µg/l and 14 µg/1, respectively EDB was detected In the ground water sample <br /> collected from well MW-2 at a concentration of 6 3 µg/l <br /> No other constituents of concern were detected in the ground water analyses at or above laboratory <br /> detection limits Analytical results of water samples collected in September 2005 are summanzed <br /> In Table 2 The laboratory report (CTEL Project No CT214-0509027), quality assurance/quality <br /> control (QA/QC) report, and chain of custody form are included in Appendix B GeoTracker <br /> confirmation pages of the submitted ground water monitoring electronic deliverable format(EDF) <br /> files are included in Appendix C <br /> r <br /> 4.0. SUMMARY AND CONCLUSIONS <br />' `,'Based on the findings from this investigation, AGE concludes <br /> The ground water elevation on-site ranged from 22 92 to 23 54 feet below MSL Ground <br /> water flow was inferred to be' flowing inward towards the southeast in the former UST <br /> - location under a gradient of 0 006-ft/ft - - _ ,` _ _ ___,- _ - � _ - <br /> • TPH-g was detected in the ground water sample collected from well MW-2 at a <br /> concentration of 210,000 µg/1 <br />' 1,2-DCA was detected in ground water samples collected from wells MW-2 and MW-3 at <br /> concentrations of 19 µg/l and 14 µg/l, respectively <br />' The lateral extent of TPH-g impacted ground water has been defined in all directions with <br /> the exception of southeast of well MW-2 <br />' Advanced GeoEnvironmental,Inc <br /> i . <br />
The URL can be used to link to this page
Your browser does not support the video tag.