My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001529
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1419
>
3500 - Local Oversight Program
>
PR0544465
>
ARCHIVED REPORTS XR0001529
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2019 1:27:42 PM
Creation date
5/16/2019 1:14:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001529
RECORD_ID
PR0544465
PE
3528
FACILITY_ID
FA0005837
FACILITY_NAME
STEFANOS GASOLINE*
STREET_NUMBER
1419
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137016
CURRENT_STATUS
02
SITE_LOCATION
1419 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> 1 1 <br /> 18 November 2005 <br /> AGE-NC Project No 03-1100 " <br />' Page 3 of 4 <br /> MW-7 to 22 67 feet below MSL in wells MW-1 and MW-2 (Table 1) The ground water elevation <br />' at the site increased an average of 1 89 feet between the February 2005 and May 2005 monitoring <br /> events <br /> , <br />' The ground water flow direction was inferred to be flowing towards the east/southeast in the former <br /> UST location at a calculated hydraulic gradient of 0 005 foot per foot(ft/ft) Figure 3 illustrates the <br />' contoured ground water elevations as measured on 12 May 2005 <br />' 3 2 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> TPH-g was detected In the ground water sample collected from well MW-2 at a concentration of <br />' 190,000 micrograms per liter (µg11) BTEX compounds were detected in the ground water sample <br /> collected from well MW-2 at a concentration of 3,000 µg11 (benzene), 12,000 pg/l (toluene), <br /> 3,400 pg/l (ethylbenzene), and 17,500 pg/1 (total xylenes) <br />' 1,2-DCA was detected In ground water samples collected from wells MW-2 and MW-3 at <br /> concentrations of 84 µg/1 and 8 6 pg/l, respectively EDB was detected 1n the ground water sample <br /> collected from well MW-2 at a concentration of 8 3 pg/1 <br /> No other constituents of concern were detected in the ground water analyses at or above laboratory <br /> detection limits Analytical results of water samples collected in May 2005 are summarized in <br /> Table 2 The laboratory report (CTEL Project No CT214-0505122), quality assurance/quality <br /> control (QA/QC) report, and chain of custody form are included in Appendix B GeoTracker <br /> - confirmation pages of the submitted ground water monitoring electronic deliverable format(EDF) <br /> files are included in Appendix C <br /> 4.0.} SUMMARY AND CONCLUSIONS <br /> Based on the findings from this investigation, AGE concludes <br /> The ground water elevation on-site ranged from 22 10 to 22 67 feet below MSL Ground Tµ <br /> water flow was inferred to be flowing inward towards the east/southeast In the former UST <br /> location under a gradient of 0 005 ft/ft y <br /> • TPH-g was detected in the ground' water sample collected from well MW,2 at a' <br /> concentration of 190,000 µg11 <br /> • 1,2-DCA was detected In ground water samples collected from wells MW-2 and MW-3 at <br /> • concentrations of 84 pg/1 and 8 6 pg/1, respectively <br /> Advanced GcoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.