Laserfiche WebLink
' 20 October. b 2003 <br />' AGE-NC Project No 95-0109 <br /> Page 2 of 4 ' <br />' Temperature, pH and conductivity of the purge water were measured at regular purge-volume <br /> Intervals using an Oakton water analyzer and the readings were recorded on field logs Field data and <br /> work sheets are Included in-Appendix A The purged-water was containerized in 55-gallon y - <br /> DOT-approved drums and stored on-site <br /> 1 <br />' 2 2 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> The depth to water was re-measured after purging to ensure a minimum of 80 per cent recharge of <br /> the initial water level in each well prior to sampling Afterwards,water samples were collected from <br /> wells MW-7 and MW-14 using a new,disposable plastic bailer and from the remaining wells using <br />' a WateraHydrolift Pump Immediately upon retrieval,the samples were transferred into 40-m1 EPA- <br /> approved volatile organic analysis(VOA)vials containing 0 5ml 18%hydrochloric acid as a sample <br /> preservative The samples were labeled, stored on Ice, and transported in a chilled container,under <br /> chain-of-custody,to McCampbell Analytical,Inc (MAD,a State of California Department ofHealth <br />' Services-certified analytical laboratory The ground water samples were analyzed for <br />' • Total petroleum hydrocarbons quantified as gasoline (TPH-g) in accordance with EPA <br /> Methods 5030/8015M, <br /> Benzene,toluene,ethylbenzene and xylenes(BTEX)in accordance with EPA method 8021, <br /> and <br /> a Fuel additives di-isopropyl ether(DIPE), ethyl tertiary-butyl ether(ETBE), methyl tertiary- <br /> butyl ether (MTBE), tertiary-amyl methyl ether (TAME), tertiary butanol (TBA), <br />�I 1,2-dichloroethane (1,2-DCA) and ethylene dibromide (EDB) in accordance with EPA <br /> Method 8260B <br /> f <br /> 3.0. FINDINGS <br /> Ground water elevation and flow direction were inferred from the field data The hydrocarbon- <br /> impact to ground water was quantified by laboratory analysis of the ground water samples <br /> 3 1 GROUND WATER GRADIENT AND DIRECTION <br /> The depth to ground water ranged from 56 12 feet to 62 26 feet below the tops of the well casings <br /> Ground water elevations at the site ranged from 2 20 feet below mean sea level(MSL)in well MW-5 <br /> . to 8 48 feet below MSL in well MW-17 Ground water levels were within the screened Intervals of <br /> water-table wells MW-1 through MW-14 and MW-16,but ranged from approximately 15 to 52 feet <br /> I , <br /> Advanced GeoEnveronmental,Inc <br />