r <br /> Project 00760.02 i <br /> 11 February 1991 ' <br /> SYSTEM MONITORING SUMMARY <br />( EVAX TECHNOLOGIES, INC. <br /> Site: Beacon Station #502 Combustor Start Up: 10/11/89 j <br /> 35 North Cherokee Lane <br /> Lodi , California <br /> System Combustor Combustor Combustor <br /> Phase Final Test Sour*Test Source Test <br /> Test Date 11/8/89 10/25%89 10/11/89 <br /> EXTRACTION TVH VP TVH i VP TVH VP <br /> POINT <br /> i <br /> VW-4 55 C 540 0 19,000 0 <br /> VW-6 50 C 65 C 5,000 0 <br /> VW-7 550 0 50 C 11,000 0 <br /> VW-5 57 C 100 C 21,000 0 <br /> MW-1 3,475 0 150 0 23,000 0 <br /> VW-9 2,800 0 6,000 '„ 0 20,000 0 <br /> Detection --- <br /> Limit (ppm) 1.0 1.01 1.0 <br /> Method TLV TLV) TLV <br /> Hours of Operation 242411 24 j <br /> Vacuum ("Hg) 3.5 1.71 <br /> ND <br /> Flowrate (scfm) 58 63.5'1 23 <br /> Influent TVH (ppm) 2,500 1,52011 22,500 <br /> Detection Limit --- -- --- <br /> (ppm) 50 5011 50 ' <br /> Method TLV - TLVI,J TLV <br /> ld ! <br /> EXTRACTION POINT — Extraction probe/well identiification as indicated on <br /> site plan. <br /> TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (O=Open) (C=CI'osed) <br /> Vacuum - System vacuum in inches of Mercury. I. fi <br /> scfm - Standard cubic feet per minute. <br /> ND - Not detected. <br /> i <br /> - 4 - <br /> li t <br />