SYSTEM MONITORING SUMMARY <br /> EVAX TECHNOLOGIES, INC. <br /> Site: Beacon Station #502 Combustor Start Up: 10/11/89 <br /> 35 North Cherokee Lane <br /> Lodi , California <br />' System Combustor Combustor <br /> Combustor <br /> Phase Final Test Source Test Source Test <br /> Test Date 11/8/89 10/25/89 10/11/89 <br /> EXTRACTION TVH VP TVH VP TVH VP <br /> POINT <br /> MW-2 55 C 540 0 19,000 0 <br /> VW-6 50 C 65 C 5,000 0 <br /> VW-7 550 0 50 C 11,000 0 <br /> MW-4 57 C 100 C 21 ,000 0 <br />' VW--8 3,475 0 150 0 23,000 0 <br /> VW-9 2,800 0 6,000 0 20,000 0 <br /> Detection --- <br /> Limit (Ppm) 1 .0 1.0 1 .0 <br /> Method TLV TLV TLV <br /> Hours of Operation 24 24 24 <br /> Vacuum ("Hg) 3.5 1 .7 ND <br /> Flowrate (scfm) 58 63.5 23 <br /> Influent TVH (ppm) 2,500' 1,520 22,500 Detection Limit --- ___ -_- <br /> (Ppm) 50 50 50 <br /> Method TLV TLV TLV <br /> EXTRACTION POINT - Extractionrob <br /> p e/well identification as indicated on <br /> site plan. <br />' TVH - Total volatile hydrocarbons in parts per million (ppm) on a <br /> volume/volume basis. <br /> TLV - Threshold Limit Values meter detects combustible gases by <br /> oxidation using a hexane standard. <br /> VP - Manifold valve position. (O=Open) (C=Closed) <br /> Vacuum - System vacuum in inches of Mercury. <br /> scfm - Standard cubic feet per minute. <br /> NO - Not detected. <br />