My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3003
>
2800 - Aboveground Petroleum Storage Program
>
PR0528317
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 11:47:46 AM
Creation date
5/17/2019 3:59:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528317
PE
2832
FACILITY_ID
FA0004400
FACILITY_NAME
STOCKTON STEEL CO
STREET_NUMBER
3003
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618002
CURRENT_STATUS
01
SITE_LOCATION
3003 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> —COUNTY— <br /> Greatness grows here. <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Phona' Data: <br /> STOCKTON STEEL CO 209 956-4751 May 15 2019 <br /> FacilityAdrkass: CERSID: <br /> 3003 E HAMMER LN STOCKTON CA 95212 10181619 <br /> Irepaction Contact: Title: Ronna: <br /> Jay Swem Plant Mana er 1209t956-4751 <br /> Inspection Type: hogern: <br /> ROUTINE INSPECTION-O eratin Permit 2832-AST FAC 10K-</=100 K GAL CUMULATIVE <br /> Consent Far: Comment G.By: <br /> Xis Ins ection Xis Photos ❑Sam les JaySwem Plant Manager <br /> CCR=Caikmm Codem F;7,iMom RSC=HeMNmd SMesy Code CFR::Tide 40 Codeof Fedend RNuldom <br /> V=NtlaEm R=Repanalmd on COS=Coneded on 9le drn9li <br /> Above¢ound Petroleum Storage Act <br /> 101 HSC 25270.6(b) Failed to pay APSA program annual fees oV in in COS <br /> 102 HSC 25270A.5(a) Failed to prepare wrieon SPCC Plan In accordance with CFR Pae 112 o V o R c COS <br /> 103 HSC 25 a6(a) Failed to ere HMBP or amuat facility tan k statem ant c c cCOS <br /> 104 HSC 25270.8 Failed to report elle or releases of 42 gallons(one barrel)or mom c c cCOS <br /> 105 CFR 112.1dX3k 112.2 Failure to property clone tanks when makln g a claim of permanently Closed c c cCOS <br /> 106 HSC 25404.1.2 Failed to submit a came cation and written resp onse wild n 30 clays for mi nor viol andiras c c cCOS <br /> 107 HSC 25270all Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion c c cCOS <br /> 108 HSC 25270A.5(a) Failure of conditionally exempt facility to conduct Inspections or Install secondary containment c c cCOS <br /> 100 HSC 25270.2(.XlXC) Feel to lave secondary containment antllor leak detection if TluGA piping cannot be keened c c cCOS <br /> (NNIII) <br /> 110 HSC 25404mi Failed to report program data In the California Environmental Reporting System(CERS) p p oCOS <br /> Requirement to Prepare and Impl emend a SPCC Plan <br /> 201 CFR 112.3(4) Failure to have a licensed PE properly renew and certify the SPCC plan in202 CFR 112.3mi Fared to maintain a copy of Me Plan on site 203 CFR 112.3 Failure to mplement the SPCC Plan 200 CFR 112.3(8) Failure to prepare SPCC Plan when radial ren Ierger meats OuailfiM Feadity criteria 205 CFR 112.3,112.fi Faame to prepare SPCC Plan that meets all applicable requirements S206 CFR 112.3(4)(1) Failure of ownerto assurethatthe PE makes all required attestations In the Plan S <br /> Amendment of SPCC Plan by Owners or Operators <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary •V .R .COS <br /> 302 CFR 112.5(b) Failed to review Plan once every Me years antllor implemerdany resuargammhents 0 p oCOS <br /> 303 CFR 112.5(c) Failetl to have a PE certify technical amendments o V o R o COS <br /> 304 CFR 112.5(a),112.5(b) Failu re to imp lem ant SPCC pl an amen tlments wthln 6 m onth s .V .R .COS <br /> Qualified Facility- <br /> 401 E( 1..26(b) Tiler Oualifietl Facility Plan not certifietl by[he owner or a PE .V .R .COS <br /> 402 Owner ofTer l Qualified Facility failed to self certfy technical amendment oV oR iCOS <br /> 403 Ran failed to predict directionlrate offiowttotal quantity of oil potentially discharged cV cR oCOS404 No 2CT far buil.containers,or mobile sterage candidness not located to prevent discharge c c cCOS <br /> FM004400 PROS]5317 SM01 OW52019 <br /> E1028101 is—iiN27rA1S Page l of7 Ahoveg J Pdrdam Sbra)e Ad OIR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjoehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.