C <br /> O O I ISOLATED GROUND FOR DIGITAL MENU BOARDS- <br /> C)z0 <br /> con GC TO VERIFY WHICH EXISTING ELECTRICAL PANELS HAS THE ISOLATED GROUND GENERAL NOTES <br /> w AND TO INSTALL THE NEW DIGITAL MENU BAORDS ON THIS ISOLATED GROUND <br /> U- <br /> U z <br /> o 0 A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. <br /> IL D1 D1 B. EMERGENCY AND NORMAL LIGHTING MARKED WITH "NL"SUBSCRIPT SHALL OPERATE <br /> o T T CONTINUOUSLY. PROVIDE UNSWITCHED HOT TO NORMAL AND EMERGENCY BALLAST. <br /> z� <br /> LL <br /> RIF C. EMERGENCY LIGHTING TO BE LEFT IN PLACE. <br /> D. ALL CONDUITS ENTERING OR LEAVING COOLER/FREEZER SHALL BE PROVIDED WITH <br /> of <br /> Lu <br /> SEAL-OFF FITTING WITH COMPOUND PER NEC 300-(7a). <br /> p F 7 F 7 F 7 F 7 E. ALL INTERIOR LIGHTING CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAYS. <br /> o F. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING <br /> Lu B- x B- x B- x Qx BB- 1 e HARDWARE. <br /> o <br /> C1W c1 W G. ALL FIXTURES SUPPLIED WITH LAMPS. <br /> Lu 8 RI O 0 0 B1 B1 E H. ALL LIGHTS SUPPLIED BY OWNER AND INSTALLED BY G.C. <br /> B 7c B-7cB- Ile B1 E I. GC TO PROVIDE INDOOR&OUTDOOR LIGHTING MEASURES TO COMPLY WITH CA T-24 <br /> o a C1 W C1 W C1 W REQUIREMENTS PER LIGHTING MANDATORY MEASURES LABELED LTG-MM AS SPECIFIED <br /> 0 0 ON SHEET T24'S. THESE INCLUDE AUTOMATIC CONTROL DEVICES, OVERRIDE SWITCH VMI JOB NUMBER <br /> o B-7a B-7a 7a B- 1e FOR BUILDING LIGHTING SHUT OFF, DAYLIGHT SWITCHES&LIGHTING CONTROL. ADJUST <br /> S C1 CO EXISTING CIRCUITING AS REQUIRED FOR COMPLIANCE. ALL EXTERIOR LIGHTS AND 18142 <br /> Lu <br /> 1 0 <br /> Lu U <br /> 0 o O I I SIGNAGE TO BE CONTROLLED VIA TIME CLOCK, "SUPPLIED BY THE GC IF NOT CURRENTLY <br /> IL B-7c B-4d 5" B- 1 h EXISTING." <br /> Q o J.PENDANT LIGHTS SHALL BE CENTERED OVER TABLES. VERIFY TABLE LOCATIONS WITH <br /> C1W C1W C1W F6 +95" <br /> IO <br /> o D1 0 0 g_g I 31 B1 E h SEATING VENDOR SUPPLIED CORE DRILL PLAN PRIOR TO LOCATING PENDANTS. �� ` �(1/Y <br /> B11 6 RI K. DOWNLIGHTS IN BLACK DROPPED CEILING SHALL HAVE BLACK TRIM RINGS. �> <br /> o m B 7a B 7a B- 7b - B- 1e L. ALL E2&EM2 FIXTURES ARE NEW FIXTURES TO REPLACE EXISTING IN EXISTING <br /> of o m I I C1 W 95" *OF <br /> LOCATIONS. ALL REPLACED EMERGENCY FIXTURES SHALL BE REPLACED WITH SAME. <br /> IL <br /> tE1 W g RI F6 %� 0 0 ( ) M. ADJUST POSITION OF AIR SUPPLY DIFFUSERS ALONG WITH THE ASSOC. DUCT WORK. <br /> B 17 E2 I B9 I B 4d B 1e N. REPLACE OR REPAIR THE EXISTING AIR CONDITION SYSTEM SO THAT IT FUNCTIONS AS IT z <br /> B-17 C1W WAS ORIGINALLY DESIGNED OR BETTER, INCLUDING A RE-BALANCE. J No. C1 79`?8 <br /> 0-0 <br /> co DI I 9R1 II II I <br /> w =5R I 0. WHERE INDICATED, LIGHTING CONTROLLED VIA OCCUPANCY SENSORS, SEE SHEET E3.0. <br /> o� F6 B-7c X1 W <br /> w W <br /> Z LL I I c0 CD I c0 I I 131-19) <br /> I I g I c0 2' 3" B1 E B-17 of C <br /> o I I B 7a B 7a B 7b I I I I B 4d (+95") I <br /> w o I I B-17 IF6 I B1 J <br /> 0o I I (+9511)-- <br /> co <br /> s co II__I I X 1 W I B I 19 I B le B- 1 e <br /> oCD <br /> U) <br /> I O I I I IF6 I CD b d B1 E D <br /> w� $19) B-4d B- 1g <br /> m= � C1W C1W I C1W I L H J C1W c X I <br /> _ _ <br /> + 4411 <br /> �� <br /> D1 B07a B 07a B�b 1. o B�7c 11 RI D GENERAL SCOPE <br /> W= L� — J B1 E I g 1O REPLACE ALL LIGHT FIXTURES (EXCEPT HOOD AND WALK-IN) <br /> w o B1 O2 RECOMISSION HVAC SYSTEM (REFURBISH AND REPLACE TO ORIGINAL SPECS) <br /> CDU B- 1g <br /> Zo <br /> az <br /> �) (1 <br /> U) C1W c1w C1W C1W GENERAL NOTES <br /> Z75 woZ O 0 O O 0 E1W B 1f <br /> U)w <br /> B 7a B 7a B 7a B 7a B1 E A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. <br /> o B. EMERGENCY AND NORMAL LIGHTING MARKED WITH "NL"SUBSCRIPT SHALL OPERATE <br /> _� 8 RI 8 RI g-17 CONTINUOUSLY. PROVIDE UNSWITCHED HOT TO NORMAL AND EMERGENCY BALLAST. <br /> LL o C. EMERGENCY LIGHTING TO BE LEFT IN PLACE. <br /> a F 7 F 7 F 7 C1W C1 W f C1W D. ALL CONDUITS ENTERING OR LEAVING COOLER/FREEZER SHALL BE PROVIDED WITH <br /> o> O O 0� <br /> O O O SEAL-OFF FITTING WITH COMPOUND PER NEC 300-(7a). <br /> wa B-9x B-9x B-9x B 7a B- 1f B- 1f h E. NOT USED. <br /> &o E1 W X1 W B 1f F. CONTRACTOR SHALL FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING RECORD DATES <br /> Lu LL 1 B-17 HARDWARE. <br /> LL o G. ALL FIXTURES SUPPLIED WITH LAMPS. DD SUBMITTAL <br /> LU LU H. DOWNLIGHTS IN BLACK DROPPED CEILING SHALL HAVE BLACK TRIM RINGS. BLDG.SUBMITTAL 3/29/2019 <br /> LU J. PENDANT LIGHTS SHALL BE CENTERED OVER TABLES. VERIFY TABLE LOCATIONS WITH <br /> LU U) Q E2 D1 BID SET <br /> B 41 D1 g_17 0 D1 SEATING VENDOR SUPPLIED CORE DRILL PLAN PRIOR TO LOCATING PENDANTS. CONTRACT SET <br /> LL 1 RI <br /> D1 12 R1 <br /> o0 <br /> ORDER KIOSK CEILING MOUNTED REVISIONS <br /> 13 RI <br /> Lu <br /> PROVIDE 20 AMP, 120 V DEDICATED CIRCUIT TO BE <br /> m INSTALLED PRIOR TO KIOSK INSTALLERS ARRIVAL I <br /> Z RI` J <br /> CEILING ABOVE. MC CABLE LEFT IN CEILING cr <br /> o <br /> w <br /> aF_ <br /> z <br /> O O <br /> wcn <br /> U)z <br /> cu =)O <br /> c0 K� <br /> O 0 <br /> o z <br /> O <br /> Lu U <br /> c� IL <br /> Lu <br /> O Z <br /> OO <br /> LIGHTING PLAN 1/4"=1'-0" p <br /> o� <br /> N Z <br /> Q cz <br /> J O OCCUPATIONAL SENSOR + 44"A.F.F. <br /> iB o <br /> cu w <br /> o o (U.O.N.)TO CENTERLINE OF SWITCH CLIENT <br /> cu <br /> I� o w (EEO POWER AND DATA FOR ORDER KIOSK. <br /> co w m $ D DIMMER SWITCHES +44"A.F.F. PRB MANAGEMENT, LLC. <br /> = U z <br /> SAFE (U.O.N.)TO CENTERLINE OF SWITCH 2 RI COORDINATE MOUNTING HEIGHT WITH EXISTING SOFFIT. <br /> w 4709 Mangels Blvd. <br /> co <br /> a � (EEO EXISTING SMOKE DETECTORS TO REMAIN. Farfield,CA 94534 <br /> 2f w HOLD UP BUTTON (MOUNT 2-1/2" DAVE FULWILER <br /> Lr-- <br /> 2f o (ERD EC SHALL INSTALL SHOW WINDOW RECEPTACLE IF NONE ARE PRESENT. <br /> LL> -E] BEHIND COUNTER EDGE) + 16"A.F.F. EC SHALL PROVIDE (1) 20A, 120V CIRCUIT BACK TO SPARE CIRCUIT IN EXISTING <br /> i o PANELBOARD. NEW CIRCUIT BREAKER SHALL MATCH TYPE AND RATING OF <br /> o => 0 J-BOX EXISTING BREAKERS. <br /> PROJECT <br /> i c NO. QUANTITY LOCATION MANUFACTURER/CATALOG NUMBER DESCRIPTION LAMP MOUNTING VOLT WATT REMARKS / 2"x 4"J-BOX W/DATA PORTS +16"A.F.F. (EEO REINSTALL EXISTING FRONT COUNTER POWER AND DATA CONNECTIONS. INCLUDE TACO BELL REMODEL <br /> co TYPE TYPE HT. IN BID REINSTALLATION OF (3) DUPLEX OUTLETS, (2) QUAD OUTLETS, (7) 2'X4"J-BOX <br /> w WITH 3/4"CONDUIT FOR DATA/PHONE AND ALL ASSOCIATED WIRING. 2407 W.MARCH LANE, <br /> �I & TCP 6"30K 90CR1 WHITE TRIM, -0 DUPLEX ISOLATED GROUND OUTLET STOCKTON,CA 95207 <br /> w C1W 28 DINING W/ELITE B6IC-AT-W 6" LED RECESSED 120 14 INCL +16"A.F.F., U.O.N. 6 RI POWER AND DATA FOR DIGITAL MENUBOARDS. <br /> o RESTROOM B61C-AT-W-LED14/DR5630KB95 ^�— — — <br /> _`' EXTERIOR ACCUSERV WALL SCONCE, CUSTOM LU100HPS WALL 7'-6"A.F.F. EXISITNG,TO REMAIN g 7 RI PROVIDE GROUND FAULT DUPLEX OUTLET FOR (N)AIR CURTAIN. INTERLOCK AIR <br /> Q z D1 8 WALL CSMBOS001/0621 1-01 5 DARK BRONZE FINISH TO CENTER 120 108 X DOUBLE DUPLEX ISOLATED GROUND OUTLET CURTAIN W/DT WINDOW. CIRCUIT TO (E) PANEL 2.5 AMPS (1 POLE 20 AMP STORE#15842 <br /> "i m o 1 +16' A.F.F., U.O.N. BREAKER). <br /> 0 o z DINING HUB TABLE 9.75"GLASS PENDANT AVERY WITH SEE (1)AAMSCO J <br /> ) F6 5 PENDANT 120 6 <br /> o w w KICHLER 4385202 OLD BRONZE FINISH LED ELEV'S LED 6W-ST64HYBRID DIM o w w 8 RI PROVIDE PRIMARY DAYLIGHT ZONE SENSOR. <br /> co ¢ 7 DINING PERIMETER TABLE 12"GALVANIZED PENDANT W/BLACK SEE (1)TCP LEDlOA19DOD27K `' U (EEO PROVIDE SECONDARY DAYLIGHT ZONE SENSOR. <br /> F7 PENDANT 120 20 <br /> �i Q Lu HI-LITES H24212-96-CB15-20WLBL-60P CORD AND CANOPY MED BASE LED ELEV'S uj <br /> ALL OUTLETS AND BOXES MOUNTED IN THE 4O <br /> 10 RI LIGHT CONTROLLED BY MOTION SENSOR. <br /> o KITCHEN/ MAXLITE RECESSED °� SERVING COUNTER CABINETRY ARE TO BE 24"AFF. L,LL,L. <br /> cu N o B1 4 2x4 LED FLAT PANEL LED 120 45 - INSTALL JUNCTION BOXES WITH CONDUIT UNDER 11 RI DIMMING SWITCH BANK WITH 2 HOUR BYPASS TO MEET TITLE 24 MANDATORY <br /> MLFP-24DE-45-41 GRID <br /> _ _ CABINET TO NEAREST WALL AND TO ABOVE MEASURES M 70 H <br /> m w B1 E g KITCHEN/ MAXLITE 2x4 LED FLAT PANEL LED SEE PLAN 120 45 CEILING. <br /> 3: RESTROOMS - 12 RI EXISTING WALL SCONCE TO REMAIN, TYP. <br /> Q w MLFP-24DE-45-41 <br /> O U Q <br /> LIGHTALARMS EXTERIOR EMERGENCY SEE KEY UNSWITCHED PROVIDE DEDICATED OUTLET FOR SAFE. <br /> o E2 2 EXTERIOR LED WALL 120 18 <br /> a CAM-SD-DB-CW EGRESS FIXTURE NOTES 'HOT' LIGHTING <br /> �� o w DINING LIGHT ALARMS 2 HEAD EMERGENCY LED WALL SEE PROVIDED WITH INTEGRAL E.C. SHALL PROVIDE A PREPRINTED <br /> ai Q z E1 W 3 KITCHEN EM-809-W WHITE ELEV'S 120 5 BATTERY PACK SELF-ADHESIVE LABEL ON ALL POS RECEPTACLES <br /> cn a STATING "POS USE ONLY". PLAN AND <br /> I--- <br /> :E <br /> X1 W 3 KITCHEN EXISTING TO REMAIN UNIVERSAL MNTG THERMOPLASTIC WALL SEE 120 2.8 PROVIDED WITH INTEGRAL <br /> :L YEw U) DINING LIGHT ALARMS EXIT, RED LETTERS-WHITE LED ELEV'S BATTERY PACK <br /> Z= G.C.TO COORDINATE DIMENSIONS WITH OWNERS SCHEDULE <br /> E �o <br /> REPRESENTATIVES. <br /> c a cn <br /> m `n o <br /> 1E z <br /> O U) <br /> 00 Fn w <br /> w Lu <br /> d � <br /> ,6 Ell ■ <br /> z <br /> cn o� <br /> Q LIGHTING FIXTURE SCHEDULE E NOT USED D (IF REQUIRED) FRONT COUNTER DETAIL C KEY NOTES B <br />