Laserfiche WebLink
1 <br /> Hazardous Waste Tank System duly <br /> Written Assessment per CCR Title 22 <br /> Tracy Toyota, 2895 Naglee Road,Tracy,CA 905304 2014 <br /> Tank Assessment Page Tank Name/marking: Waste Coolant <br /> Tank age: Estimated at 13 years <br /> Remaining service life: 20 years, inspect at 5 <br /> years <br /> Tank Construction: <br /> Shape: Cylindrical, Vertical, Closed Top <br /> Orientation: Vertical <br /> Location (above/below ground): Above Ground <br /> Material of construction: Polyethylene <br /> Thickness and method used to determine: 0.37 in., UTG <br /> Lining material & thickness (if applicable): not applicable <br /> Corrosion Protection equipment: Tank is compatible with antifreeze <br /> Structural support: Mounted on floor and is anchored to prevent shifting. <br /> Other identifying features: Open top with hand way at top. Fitted with <br /> overfill sensor and alarm <br /> Piping and ancillary equipment (pumps): Graco Husky 307 <br /> Piping Material of Construction: <br /> Piping Diameter: 1-inch schedule 40 galvanized steel pipe. <br /> Pump location(s): On wall outside of petroleum storage room. <br /> Pump type(s)/capacities: Air Operated Diaphragm Pump, 3 gpm <br /> Material Storage: Waste Antifreeze - - - - <br /> Material and characteristics non-RCRA hazardous waste <br /> Specific Gravity: 1.05 <br /> Operating Capacity: 215 gallons <br /> Chemical compatibility findings: The materials identified above are patible <br /> for contact with or proximity to the equipment, tank or tank system int s <br /> assessment. Initials: <br /> i <br /> c <br /> Strandberg Associates 1(866) 388-0404 rwatercluyCcr7rwaterguuy.com 14 <br /> l <br />