10/11/2002 13:06 707-58F 0900 VERTEX ENG PAGE 08/13 <br /> • The VOC sample containers will be filled and scaled without headspace or bubbles; <br /> • Groundwater samples will be stored in an ice cooler at approximately 4°C; <br /> • Chain-of-Custody forms will be completed and taped to the inside lid of the cooler; <br /> Upon completion of the groundwater sampling, each borehole will. be abandoned using the <br /> tremie grouting method. VERTEX will arrange with San Joaquin County Environmental Health <br /> Department staff to observe the grouting procedure at the site to ensure that this work is <br /> performed to their satisfaction. <br /> Decontamination of equipment will be performed to reduce the potential for transport of <br /> contaminants off-site and between work areas. Decontamination of drilling equipment and <br /> monitoring well materials will occur if necessary, at the designated decontamination station. <br /> Any parts of the drill rig that are encrusted with dirt or mud or are suspected of having been <br /> splashed with materials at a sampling station will be washed with high pressure water and steam <br /> prior to moving to the next borehole location. Drill rigs may be protectcd with plastic sheeting to <br /> minimize contamination of major body parts. The drilling and sampling equipment will be <br /> washed with Alconox and water, then rinsed with clean water. New disposable bailers or Teflon <br /> tubing will, be used at each sampling location. Decontamination water will be, containerized and <br /> disposed of in an environmentally safe manner. <br /> A total of four (4) groundwater samples will be collected and submitted to a DHS-certified <br /> laboratory using chain-of-custody protocol. In addition, for quality assurance/quality control <br /> (QA/QC) one trip blank will be prepared and. submitted to the Laboratory using chain-of-custody <br /> protocol. The laboratory will analyze all. samples for the following parameters: <br /> • VOC's by EPA Method 8260, including Fuel Oxygenates <br /> Water sample analysis will undergo formal QA/QC data validation at the laboratory to ensure <br /> that data are of acceptable quality. <br /> SunStar Laboratories, Inc. of Tustin, California is scheduled to analyze all groundwater, and <br /> QA/QC samples. The turnaround time from sample collection to the submission of analytical <br /> results is expected to be approximately 24-hours, The slipping address for SunStar Laboratories <br /> is presented below: <br /> SunStar.La.boratories,Inc. <br /> 3002 Dow Avenue, Suite 406 <br /> Tustin,Califomia 92780 <br /> The samples will be collected into pre-cleaned certified containers. SunStar Laboratories will <br /> provide these containers and appropriate preservatives. Sample containers will be ICHEM 200 <br /> series or equivalent. Samples will be placed immediately after collection into coolers for storage <br /> and shipment. At least two bags of ice, sealed in double plastic bags (or packets of blue ice)will <br /> 4 <br />