Laserfiche WebLink
EVAX TECHNOLOGIES, INC <br /> SYSTEM MONITORING SUMMARY <br /> EXTRACTION WELLIPROBE SUMMARY <br /> SITE Beacon Station #695 <br /> 900 South Cherokee Lane <br /> Lodi, California TABLE I (cont) <br /> EXTRACTION WELL <br /> VW-26 RW-1 <br /> DATE TVH VP TVH VP <br /> 12/29/92 <br /> 12/14/92 500 O 400 C <br /> 12/01/92 325 O 100 C <br /> 11/20/92 125 O 6,000 O <br /> 11/17/92 O 0 <br /> 11/03!92 500 O 5,000 O <br /> 10/20/92 325 O 4,000 FO O <br /> 10/05/92 300 O 4,000 FO O <br /> 09/22/92 200 O 3,000 O <br /> 09/08/92 300 0 5,000 O <br /> 08/26/92 400 0 10,000+ O <br /> 08/13/92 450 O 3,200 GC O <br /> 07/28/92 1,300 O 180 O <br /> EXTRACTION POINT-Extraction probe/well identification as indicated on site plan <br /> INTERVAL-Screened interval or perforated range of well or probe in fed below grade <br /> TVH-Total volatile hydrocarbons in pails per million(ppm)on a volumelvolume basis <br /> OVA-Organic Vapor Analyzer <br /> FID-Flame Ionization Detector <br /> VP-Manifold valve position(O=Open) (C=Closed) <br /> FO-FID Flame Out,generally due to high concentrations and low oxygen <br /> H2O-Water in Extraction Line <br /> ND-Not Detected <br /> NT-Not Tested <br /> NA-Not Available <br />