EHD Program Facility Records by Street Name
>
B
>
B
>
1604
>
2800 - Aboveground Petroleum Storage Program
>
PR0515766
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2019 8:48:47 AM
Creation date
5/24/2019 1:55:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515766
PE
2832
FACILITY_ID
FA0003683
FACILITY_NAME
Caltrans-Stockton
STREET_NUMBER
1604
Direction
S
STREET_NAME
B
STREET_TYPE
St
City
Stockton
Zip
95206
APN
171-090-08
CURRENT_STATUS
01
SITE_LOCATION
1604 S B St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tank Details <br /> Tank Location # Convault(A) Onan Cummins(B) <br /> Contents Unleaded Gasollne Diesel Fuel <br /> capacity 6000 gal 79 gal <br /> Site IN " Fueling Center Electricians Bldg <br /> Manufacturer ConVault Onan Cummins <br /> Date August 1997 November 1997 <br /> UL2085-Protected UL 142 AST for Standby <br /> Specification I Tank Generator System <br /> UL# M297653 No Plate <br /> Dimensions 6000 gal 79 gal <br /> Category 1 1 <br /> Orientation Horizontal Horizontal <br /> - Elevated Tank for Elevated Tank for <br /> CRDM, visual Inspections visual inspections <br /> Continuous Release Detection Method (CRDM) <br /> ConVault Tank: (1) AST elevated 6 inches above floor, which may be visually inspected <br /> underneath AST, with (2) Double-Wall Integral Secondary Containment on ConVault AST (3) <br /> Overfill protection, mechanical product inventory monitoring and visual inspections being <br /> performed, (4)continuous mechanical gauge leak detection. <br /> Onan Cummins Tank: (1) AST elevated 6%z inches above floor, which rosy be visually <br /> inspected underneath AST, with (2) Double-Wall Integral Secondary Containment an Onan <br /> Cummins "belly tank" AST located beneath the generator, (3) Overfill protection, mechanical <br /> product inventory monitoring and visual inspections being performed, (4) AST sits within <br /> concrete containment berm. <br /> Spill Protection <br /> ConVault Tank: Product off load area is contained by Spill Containment Operations in which <br /> filler uses camlock connections, with overfill containment Baker Box for overfill operations, <br /> This Baker Box has a manual pump to pump fuel in the basin of the Baker Box back into the <br /> AST. At time of inspection there were no shut down device or limiting devices, such as <br /> Morrison Bros or a Guillotine fill limiting devices as a further protection against overfilling. . <br /> Gene Cummins Tank: Product off load area is contained by operator at the AST during filling <br /> operations, wherein the fill port is opened, a fill hose inserted into the fill port and filling <br /> commenced. The operator can visually monitor the filling operations to ensure that no spills <br /> occur. Should such a spill occur, the product would be contained at the site by the concrete <br /> berm. There are no other devices which would serve as Spill Containment for this tank system . <br />