My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COMCONEX
>
17333
>
2800 - Aboveground Petroleum Storage Program
>
PR0518597
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 1:51:07 PM
Creation date
5/24/2019 4:35:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0518597
PE
2832
FACILITY_ID
FA0011214
FACILITY_NAME
ATS MANTECA
STREET_NUMBER
17333
Direction
S
STREET_NAME
COMCONEX
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20818018
CURRENT_STATUS
01
SITE_LOCATION
17333 S COMCONEX RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
American Paving Systems, Inc. <br /> If Measures listed in 40 CFR 112.7(c) are not Practicable <br /> 40 CFR 112.7(d) <br /> All measures noted in 40 CFR 112.7(c)are practicable, are in place, in use and no items <br /> need to be addressed in 40 CFR 112.7(d). <br /> Inspections, Tests & Records 40 CFR 112.7(e) <br /> All oil product handling employees of American Paving Systems, Inc. will be trained to <br /> observe the aboveground storage tanks, valves, associated pumps, aboveground piping, oil drum <br /> storage area, and dispensers for potential problems. if a problem is observed, the employee shall <br /> inform management,who will in turn take the necessary action. The area where the delivery truck <br /> parks is located just south of the concrete containment area. Any discharge or spill that cannot be <br /> contained will flow southeast and be contained on site. The 42 Diesel tank loading area is contained <br /> within the concrete containment area. The delivery truck is parked next to the containment <br /> structure in the parking lot area. The delivery hose is connected to the #2 Diesel Fuel is loaded <br /> through a fill/spill box inside the controlled fencing. <br /> The forms found in Appendix B, C, and D are to be used to record the inspections. All <br /> aboveground storage tanks, valves, aboveground piping, spill control areas, secondary <br /> containment, and emergency response equipment and supplies shall be inspected monthly by <br /> American Paving Systems,Inc.'s employees. Each inspection shall be recorded,dated,signed,and <br /> placed in the appropriate Appendix of this SPCC Plan. All items requiring attention will be noted <br /> and corrective action taken before the item is deemed to be in compliance. The dispensing area is <br /> inspected monthly and any defects, spills, or stains are reported to management for corrective <br /> action. <br /> All vegetation is controlled and no vegetation is allowed to grow in the fuel oil products <br /> containment system. Combustible garbage type and debris are also controlled and no accumulation <br /> is permitted in the oil product storage and containment areas. Preventive maintenance actions are <br /> incorporated into American Paving Systems, Inc.'s operation and housekeeping measures are <br /> established. <br /> Tanks are labeled to show the oil product that they contain and to express the reactivity <br /> and hazard of the oil product within the storage tank.No tank is allowed to sit on the ground with <br /> direct contact to soil. All surfaces of the oil product tanks can be and are inspected monthly for <br /> possible compromise to their integrity. <br /> Any and all testing and certification records, as appropriate, will be maintained in this <br /> SPCC Plan for five years or in the appropriate maintenance report log for the regulatory agency <br /> that has jurisdiction on the testing requirements. Certified Non-Destructive Testing was performed <br /> on May 17, 2019. <br /> f <br /> 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.