Phase II Environmental Site Assessment <br /> 1645 Cherokee Lane,Stockton,CA <br />' Hydro-Environmental Technologies,Inc <br />' 1.0 SITE LOCATION AND BACKGROUND <br />' The subject property is at 1645 Cherokee Lane, Stockton, California, north of the intersection of <br /> Cherokee Lane and Waterloo Road It is in T2N, R6W of the 1968 (revised 1987) Stockton West, <br /> California 7 5 minute (124,000) Quadrangle The property is approximately 21 feet above mean sea <br />' level (AMSL) <br /> The subject property is in an area of mixed light-industrial and commercial buildings, it is part of a <br />' property used to repair railroad engines by the Central California Traction Company In January 1999, <br /> Thorpe Oil Company excavated and removed one 6,000-gallon gasoline underground storage tank (UST) <br /> and one 1,000-gallon diesel UST from the subject property One soil sample, collected from below the <br />' excavated diesel tank at 9 feet below surface grade(bsg), had 8,000 milligrams per kilogram(mg/kg) total <br /> petroleum hydrocarbons (TPH) as diesel, 0 33 mg/kg toluene, 0 740 mg/kg ethylbenzene, and 1,800 <br /> mg/kg total xylenes, benzene was below method detection limits <br />' Hydro-Environmental Technologies, Incorporated (HETI) reviewed the September 1999 URS Greiner <br /> Woodward Clyde (URSGWC) final report UST Investigation, 1645 Cherokee Lane, Stockton, CA In <br /> August 1999, URSGWC conducted a soil bonng/ground water investigation Five borings were drilled <br /> using direct push (DP) and hollow stem auger The highest TPH as diesel concentrations (at 22,000 <br /> mg/kg) in soil were detected in samples collected from boring B-1 at the 10-foot depth interval <br /> However, TPH as diesel was detected in soil samples collected from the entire soil boring to ground <br />' water Concentrations ranged from 6,000 mg/kg (at 15-feet bsg) to 2,000 mg/kg (at 40-feet bsg) <br /> Ethylbenzene and total xylenes were also detected ranging to 0 011 mg/kg and 0 061 mg/kg, respectively <br /> at 10 feet bsg <br /> TPH as diesel was also detected in soil samples collected from boring B-2 (38 mg/kg at 12 feet bsg), <br /> boring B-4 (27 mg/kg at 10 feet bsg) and boring B-5 (19 mg/kg at 10 feet bsg, 1 1 mg/kg at 20 feet bsg, <br />' 1,800 mg/kg at 25 feet bsg and 3,200 bsg at 31 feet bsg) <br /> In their November 4, 1999 letter, the San Joaquin County Public Health Services, Environmental Health <br />' Division (PHS/EHD) requested a further investigation to determine the lateral and vertical extent of the <br /> petroleum contamination at the subject property On June 15, 2000, Ms Lori Duncan, Senior REHS with <br /> the PHSIEHD, approved the work plan prepared by HETI (See Appendix A) HETI then installed six DP <br /> borings throughout the subject property Grab ground water samples were obtained from each boring <br /> HETI then installed three ground water monitoring wells to determine ground water flow direction and <br /> gradient <br />' Figure 1 is a site location map, Figure 2 is the DP soil boring and ground water monitoring well locations <br /> map <br /> 1 <br /> 1 <br />