Laserfiche WebLink
�. .. <br /> Tom" <br /> ti <br /> i <br /> E <br /> t <br /> s <br /> 6 <br /> Fs; <br /> f:\pr0jccts\53I-0G1\usircp <br /> t ap <br /> Soil Sample HA-2, taken from beneath rubber shavings approximately 150 feet from the <br /> fuel islands contained nondetectable level's of oil and grease, TPH as gasoline, diesel, and <br /> motor oil, and BTEY.- The sample contained a small amount of total lead,4.9 ppm. <br /> The laboratory reports and chain of custody documents for the soil samples are contained <br /> in Appendix G <br /> Figure 2 is a plan view contour map showing the approximate depth to soil containing less ' <br /> than 10 ppm.7PH- asoiine. This map shows that the soil containing hydrocarbons extends <br /> 1 to a depth of 50 feet in the immediate vicinity of the product lines, but is shallower <br /> 3 7 elsewhere. The map also shows the apprwamate areal extent of hydrocarbons in the <br /> subsurface. <br /> Figure 3 is a cross-section constructed through the borings along the product lines to <br /> demonstrate the vertical distribution of hydrocarbons in the subsurface. This section shows <br /> that the deepest penetration of hydrocarbons in the soil is apparently on the east side of <br /> j the product.lines. In particular, Boring B11 showed detectable levels of hydrocarbons to <br /> a depth of 50 feet. This figure also demonstrates how OVA readings and Iaboratory <br /> analyses were used to assess the vertical extent of hydrocarbons in the soil. <br /> Conclusions <br /> l� This investigation assessed the approximate lateral and vertical extent of hydrocarbons in <br /> the soil beaeath the fueling area and underground storage tanks at this site. The main <br /> r ; concentration of hydrocarbons appears to be limited to an area immediately surrounding <br /> the product lines,which have leaked in the past- The deepest penetration of hydrocarbons <br /> in the soil appears to be 50 feet, in the immediate vicinity of Boring B11. There is also <br /> evidence of hydrocarbons to a depth of 20 feet in the soil east of the underground storage <br /> E <br /> tanks, near Boring B2. <br /> Ground water is apparently deeper than fifty feet at the site and may not be affected by the <br /> hydrocarbons in the soil. However, a monitoring well may be necessary to determiny thy- <br /> dept`s to ground and to assess the presence or,absence of hydrocarbons in the ground <br /> water. <br /> f <br /> Soil samples obtained from Wither areas on site, particularly near the former locations of <br /> waste oil tanks, indicate no significant amounts of hydrocarbons, or other potentially <br /> j hazardous material, have been released in the subsurface, <br /> t . <br /> { <br />