Laserfiche WebLink
Environmental <br /> Science & <br /> Engineering,Inc XCRJYTrII'///IrI'���+■'tI <br /> A Ci4MRP C..� .y V <br /> A JUN 3 0 1993 <br /> June 28, 1993 <br /> ENVIRONMENTAL HEALTH <br /> Project 6-92-5400 PERMIT/SERVICES <br /> Cecchini, Cecchini, &c Giovannom <br /> C/O Mr. Ellis Cecchini IeL� <br /> 1312 A. Street / <br /> Antioch, California 94509 /�11C1 <br /> SUW ECT: SlzC®I�D QUAmimm 05)5 <br /> GROUND WATER 1` O1\ZTORffi\G REPORT <br /> 3535 E. CHEROKEE RGAIID, STOCK'I ON, CAILIIIFORNM <br /> Dear Mr. Cecchini- <br /> The following report documents Second Quarter 1993 Ground dater Monitoring for the <br /> fueling island area of the subject site. One well, designated UST-1, is located in the fueling <br /> island (Figure 1 - Site Plan). Well UST-1 has had problems with leakage of fuel from the <br /> surface and has been repaired twice within the last year. The latest repair was made in <br /> ® March 1993 when ESE placed a second cover and re-fitted the water tight seal on the well. <br /> The well has been in a quarterly monitoring program since October of 1992. The first <br /> quarter 1992 monitoring was delayed due to repairs needed on the well. <br /> Mork Performed This Ouarter <br /> On April 23, 1993, Environmental Science &L Engineering, Inc. (ESE) staff, in the presence <br /> of Mr. Michael Infurna of San Joaquin County Department of Environmental Health <br /> q ty P <br /> cleaned the well of debris using a pressure washer fitted with hosing n <br /> (County), g p g a d lowered <br /> down the entire length of the well Approximately 40 gallons of water was used to clean the <br /> well by this method The source of the water for cleaning was the facility drinking water <br /> supply (hose bib). Approximately 40 gallons of fluids which entered the well during the <br /> cleaning process were evacuated by hand bailing on April 23 All fluids evacuated from the <br /> well were stored in drums and remain on site. <br /> On April 28, 1993, ESE measured water levels and purged and sampled well UST -1. ESE <br /> first measured the static water level in the well using an electronic water level sounder. <br /> Then, using a electric submersible pump, approximately 150 gallons of water were purged <br /> from the well. During the purging process, pH, temperature and conductivity were <br /> measured. The well purging was considered complete when a minimum of three well <br /> volumes were evacuated, the final field measurements of pH, temp and conditions were <br /> within 15 percent of the prior measurement and the purged water was clear The ground <br /> water sample was then collected from well UST-1 by lowering a new (precleaned) <br /> O disposable polyethylene bailer in the well using new, disposable nylon cord The filled bailer <br /> 4090 Neltion Avenin Suite] Cona.ord CA 94520 Phone(5711)685 4093 Far(510)6b5-5321 <br />