My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001952
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
3535
>
3500 - Local Oversight Program
>
PR0544497
>
ARCHIVED REPORTS XR0001952
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 3:44:27 PM
Creation date
5/28/2019 3:29:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001952
RECORD_ID
PR0544497
PE
3528
FACILITY_ID
FA0003687
FACILITY_NAME
OLD TRUCK STOP, THE
STREET_NUMBER
3535
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13206009
CURRENT_STATUS
02
SITE_LOCATION
3535 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 26 January 2004 <br /> AGE-NC Project No 97-0312 <br />' Page 2 of 4 <br /> In addition,the large on-site domestic well was purged and sampled on 12 December 2003 To purge <br /> the large domestic well, a drain valve was opened on the water storage tank and the pump was <br /> allowed to cycle on and off for approximately 15 minutes The small domestic well was out of <br />' service,the electrical service was disconnected and the distribution piping was truncated and capped <br />' 2 2 COLLECTION OF GROUND WATER SAMPLES l <br /> The depth to water in the monitoring wells was re-measured following purging to assure a minimum <br />' of 80%recharge prior to sampling Water samples were retrieved from each purged monitoring well <br /> using a Waterra inertial pump To sample the large domestic well,a sampling port was opened at the <br /> well head and samples were collected from the sampling port while the pump was operating to <br />' obtain fresh water samples Each sample was transferred into four laboratory-supplied 40-m1 EPA- <br /> approved volatile organic analysis (VOA) vials containing 0 5 ml of 18% hydrochloric acid as a <br /> sample preservative and into one 1-liter amber bottle without preservative <br />' The samples were labeled, laced in a chilled container and transported under chain-of-custody to <br /> p p <br /> . McCampbell Analytical Inc (MAI), a California Department of Health Services (DHS)-certified <br />' analytical laboratory in Pacheco The samples were analyzed for <br /> • Total petroleum hydrocarbons quantified as gasoline (TPH-g) and diesel (TPH-d) In <br />' accordance with EPA Methods 5030/8015m and 3550/8015m, respectively, <br /> Benzene, toluene, ethylbenzene and total xylenes (BTEX) and the fuel additives methyl <br />' tertiary-butyl ether(MTBE) in accordance with EPA Method 8021B, <br /> • Fuel additives including dl-isopropyl ether(DIPE),ethyl tertiary-butyl ether(ETBE),MTBE, <br /> tertiary-amyl methyl ether(TAME) and tertiary-butanol (TBA), 1,2-dibromoethane (EDB) <br />' and 1,2-dichloroethane (1,2-DCA) in accordance with EPA Method 8260B, and <br /> • Halogenated volatile organic compounds(HVOCs)in accordance with EPA Method 8021 B <br /> 1 - <br /> 3.0. FINDINGS <br /> 1 <br /> Ground water elevations were determined by subtracting the measured depths-to-water from the <br />' surveyed casing elevations (Table 1) Ground water flow direction was determined by contouring <br /> the water elevations on a scaled site plan (Figure 3) Hydrocarbon-impact to ground water was <br /> assessed by laboratory analysis and field observations <br /> 1 <br />' Advanced GeoEnvi ron mental,Inc <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.