Laserfiche WebLink
STATE OF CALIFORNIA--HEALTFI AND WELFARE AGENCY GEORGE DEUKMEJIAN, Gorornor <br /> DEPARTMENT OF HEALTH SERVICES <br /> 714/744 P STREET n< <br /> SACRAMENTO, CA 95814 p ; <br /> ATTACHMENT I <br /> Subject: Geohydrological Investigations Draft Engineering <br /> Report - Defense Depot Tracy <br /> The comments below concern the geology and hydrologeology <br /> aspects of the above cited document and the undated <br /> (received June 12 , 1986) proposed Scope of Work (SOW) fof <br /> the continuation of the investigation at Defense Depot Tracy <br /> (DDTC) . <br /> 1) In general, the report was well written and complete. <br /> Radian' s inclusion of daily logs, sieve analysis, and raw <br /> data was helpful in our review. This data is not always <br /> included .in a report and is usually requested during the <br /> review process, thereby delaying the process. DHS endorses <br /> Radian' s recommendations for off Depot work and the <br /> installation of additional on Depot wells to further <br /> delineate suspected source areas. <br /> 2) The report could benefit from additional geologic cross <br /> sections. Only one section is included in the report. At <br /> least two, and preferably four sections are needed. A fence <br /> diagram would also be helpful . The purpose of cross <br /> sections and fence diagrams is to show the author' s <br /> interpretation of the geology across the areas of interest. <br /> This is essential in determining preferred migration <br /> pathways for vapor and water and for evaluating conclusions <br /> dependent on geology, such as pump test results and monitor <br /> well screen locations. The location of upper and lower <br /> confining beds and/or water table should be emphasized in <br /> these cross sections. <br /> 3) The SOW for this draft report included a pump test <br /> (section 3 .2 . 4) . However, it appears that one was not <br /> conducted. In this report Radian recommends conducting an <br /> aquifer pump test (see section 6 . 0. 4) for the next phase of <br /> work. However, one is not included in the SOW for the next <br /> phase. A pump test must be conducted to identify the <br /> aquifer characteristics reg.0 ad to evaluate the geometry <br /> and rate of movement of the plume. As stated by Radian in <br /> section 3 . 2 . 40, a larger diameter well will be required to <br /> conduct the pump test. Note that slug tests are not a <br /> substitute for an aquifer pump test(s) . <br />