My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
25700
>
2900 - Site Mitigation Program
>
PR0508450
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 11:58:23 AM
Creation date
5/29/2019 11:10:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508450
PE
2960
FACILITY_ID
FA0008087
FACILITY_NAME
DDJC-TRACY
STREET_NUMBER
25700
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25207002
CURRENT_STATUS
01
SITE_LOCATION
25700 CHRISMAN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Off-Site Domestic Supply Wells -2- 22 November 1991 <br /> DDRW, Tracy <br /> I believe that it is premature for DDRW, Tracy to state that it is not the source of <br /> the carbon tetrachloride for the following reasons (as discussed in a telephone <br /> conversation with Mr. Marshall Cloud at DDRW, Tracy on 15 November 1991) . <br /> 1. The site-wide Remedial Investigation (RI) has not been completed. All of the waste <br /> management units (WMUs) have not been investigated in the southern end of the site. <br /> Therefore, there are no data to indicate whether or not wastes from these WMUs have <br /> impacted ground water. DDRW, Tracy's claim regarding it not being the source of <br /> carbon tetrachloride (or any other ground water contaminant) from that area cannot <br /> be verified until further sampling, as part of the site-wide RI, has been <br /> completed. <br /> 2. DDRW, Tracy has not developed an adequate historical water level data base. <br /> Because site-wide ground water level measurements have not been conducted at the <br /> site on a consistent basis, potential seasonal influences on flow direction have <br /> not been determined. In addition, due to a lack of monitor wells at the southern <br /> and southeastern portions of the site, potential easterly ground water flow <br /> components cannot be verified. If the previously reported ground water flow <br /> direction of northeasterly is correct, then the southern end of the site would be <br /> directly upgradient from the Rose and Robertson residences. WMUs in the southern <br /> end of the DDRW, Tracy site are potential sources of VOC ground water <br /> contamination. <br /> 3. DDRW, Tracy has not developed an adequate historical water quality data base. Many <br /> existing wells across the site have not been sample on a consistent basis and <br /> analyses for minerals have generally not been performed. This information is <br /> needed to fingerprint the water quality both on- and off-site. <br /> 4. The quarterly ground water monitoring program has been implemented only within the <br /> last year and therefore, has not yet collected four quarters of data. In addition, <br /> the ground water monitoring program has never included monitoring of off-site <br /> supply wells. <br /> 5. DDRW, Tracy has conducted only one off-site well survey in 1987. This survey may <br /> have been incomplete and may now be out of date. An off-site well survey is <br /> critical to determine what wells may be potentially impacted by a contaminant plume <br /> and to determine what wells could potentially affect the migration of the plume. <br /> Monthly monitoring of the domestic wells appears to be excessive. Monthly monitoring <br /> of the Rose and Robertson residences, and any other potentially affected drinking water <br /> wells, over an extended period, would be unnecessary if bottled water was supplied as <br /> an interim measure. This excessive monthly monitoring would triple the analytical <br /> costs incurred by DDRW, Tracy. DDRW, Tracy should instead supply the bottled water to <br /> the Robertson residence, as soon as possible. This would eliminate the need for <br /> monthly ground water monitoring of these residences. As previously recommended, <br /> quarterly monitoring of off-site supply wells should be implemented by DDRW, Tracy as <br /> soon as possible. <br /> Of critical importance to this issue is the fact that within several acres of the <br /> eastern end of the DDRW, Tracy, there are at least three other potential source areas, <br /> besides DDRW, Tracy, of volatile organic ground water contamination. These other <br /> potential source areas are listed below. <br />
The URL can be used to link to this page
Your browser does not support the video tag.