WASTE DISCHARGE REQUIREMENTS -9- <br /> DEFENSE DISTRIBUTION REGION WEST TRACY <br /> SAN JOAQUIN COUNTY <br /> 6. The Discharger shall notify the Board and the Department of Health <br /> Services, within 24 hours, of any shutdown of the interim ground water <br /> system. This notification shall include the cause of the shutdown and <br /> the corrective action taken (or proposed to be taken) to restart the <br /> system. <br /> 7. The Discharger shall notify the Board and the Department of Health <br /> Services, within 24 hours, of any spill associated with the operation <br /> of the interim ground water system. This notification shall include <br /> the size and cause of the spill , any immediate damage to the <br /> environment, and the corrective/cleanup actions taken and/or proposed. <br /> 8. The Discharger shall submit to the Board and the Department of Health <br /> Services the "Monthly Operation Reports" by the 15th day of the <br /> following month. These operational reports should contain a summary <br /> of the 0&M activities for that month, including those activities <br /> contained in the Preventive Maintenance Schedule, prepared by <br /> Ensotech, Inc. (dated 22 March 1990 and any subsequent updates) , and <br /> in Discharge Specification C.4. (vi) . In addition, the Monthly <br /> Operation Report shall contain a summary of any shutdown and/or spill <br /> events that occur that month. <br /> 9. The Discharger shall submit to the Board and the Department of Health <br /> Services all revisions to the "Preliminary Ground Water Model Report" , <br /> dated 24 March 1990. In addition, the Discharger shall provide to <br /> both the Board and the Department of Health Services the "Model <br /> Operations Manual" for the ground water contaminant transport model , <br /> including software, data, and operating instructions. <br /> 10. The Discharger shall submit to the Board and the Department of Health <br /> Services the "IRM Evaluation Report" and the "System Evaluation <br /> Report". The "System Evaluation Report" shall determine if the <br /> performance monitoring well network (MW-1 through MW-10 and the nearby <br /> RI/FS monitoring wells) provides sufficient hydrologic and water <br /> quality data to accomplish the following objectives: <br /> a. Monitor water levels and water quality within the permeable zone <br /> screened by the extraction wells, and within overlying and <br /> underlying zones. <br /> b. Verify that the capture zones of individual extraction wells <br /> overlap (i.e. , no gaps exist) , and that off-Depot migration of <br /> contaminants is being reduced in the vicinity of the extraction <br /> field. <br /> C. Determine hydrogeologic and water quality parameters of the <br /> ground water regime in order to adequately calibrate the ground <br /> water contaminant transport model. <br />