My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
25700
>
2900 - Site Mitigation Program
>
PR0508450
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 11:58:23 AM
Creation date
5/29/2019 11:10:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508450
PE
2960
FACILITY_ID
FA0008087
FACILITY_NAME
DDJC-TRACY
STREET_NUMBER
25700
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25207002
CURRENT_STATUS
01
SITE_LOCATION
25700 CHRISMAN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a � <br /> Enseco <br /> I Sample Description <br /> See the attached Sample Description Information. <br /> The samples were received under chain-of-custody. <br /> II Analysis Request <br /> The following analytical tests were requested. <br /> Lab ID Analysis Description <br /> 047222-1 Aromatic Volatile Organics <br /> -2, 3 Halogenated Volatile Organics <br /> III Quality Control <br /> A. Proiect Specific QC. No project specific QC (i .e. , spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> No target parameters were detected in the method blanks associated <br /> with your samples at the reporting limit levels noted on the data <br /> sheets in the Analytical Results section. <br /> C. Laboratory Control Samples - The LCS Program <br /> Duplicate Control Samples. A DCS is a well -characterized matrix <br /> (blank water, sand or celite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The DCS <br /> results associated with your samples are on the attached Duplicate <br /> Control Sample Report. <br /> Accuracy is measured by Percent Recovery as in: <br /> recovery = (measured concentration) x 100 <br /> (actual concentration) <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in: <br /> RPD = (% recovery test 1 - % recovery test 2) x 100 <br /> (% recovery test 1 + % recovery test 2)/2 <br /> Control limits for accuracy (percent recovery) are based on the average, <br /> historical percent recovery +/-3 standard deviation units. Control limits <br /> for precision (relative percent difference) range from 0 (identical <br /> duplicate DCS results) to the average, historical relative percent <br /> difference + 3 standard deviation units. In cases where there is not <br /> enough historical data, EPA limits or advisory limits are set, with the <br /> approval of the Quality Assurance department. <br />
The URL can be used to link to this page
Your browser does not support the video tag.