Laserfiche WebLink
Table 1. Summary of VOC Contaminated Sites page 1 <br /> South Balloon-Plume 1 <br /> VOC Site Historic Jy" Descrintion Current G. Required <br /> TCE ppbv Hydropunch/quarterly ug/l Action <br /> P-IA 79,700 ppbv Design Max TCE 21,000 ppbv 12/18 Implement ISV <br /> P-11) 193,000 ppbv Design Max TCE 57,000 ppbv ND/0.6 Implement ISV <br /> P-1C 12,400 ppbv Design Max.TCE 10,000 ppbv 1400/14 Implement ISV <br /> Max. PCE 860 ppbv <br /> P-1 D 37,200 ppbv Design All samples below 350 ppbv ND/ND No Further Action <br /> P-IF 3,930 ppbv Chars. All samples below 350 ppbv 82/NS No Further Action <br /> P-IE 2,156 ppbv Chara. Max.TCE 1400 ppbv 430203 Implement ISV <br /> Max. PCE 830 ppbv <br /> Max. 1,2 DCA 200 ppbv <br /> P-IG 2,929 ppbv Chars. All samples below 350 ppbv 380/330 No Further Action <br /> P-213 500 ppbv Chars. 5 of 42 samples exceed 2.2/NS Model impact to <br /> 350 ppbv standard Water Quality <br /> Central Area-Plume 2 <br /> VOC Site Historic T)= Description Current G.W Required <br /> TCE ppbv Hydropunch/quarterly ug/1 Action <br /> P-2A 1,413 ppbv Chars. 6 of 28 samples exceed 0.78/1.5 Model impact to <br /> 350 ppbv standard Water <br /> Quality <br /> Central AreaPlume 3 <br /> VOC Site Historic 1ti Description Current G. Required <br /> TCE ppbv Hydropunch/quarterly ug/I Action <br /> P-3A 1,546 ppbv Chars. 3 of 43 samples exceed 3722 Model impact to <br /> 350 ppbv standard Water Quality <br />