Laserfiche WebLink
4. Table B-2, Well LM025AUA <br /> Table B-2 states that well LM025AUA is "not within 100 feet of an <br /> extraction well. " As a result, per the Sampling Frequency Decision Flow <br /> Chart (Figure 2-1) , the sampling frequency for this well was determined <br /> to be annual sampling. However the coordinates of LM025AUA in the <br /> Annual Monitoring Report, Table 2.5-1, indicate the well is 9 feet from <br /> extraction well EW037AU. Thus, the statement cited above in Table B-2 <br /> is incorrect. Per the Sampling Frequency Decision Flow Chart (Figure 2- <br /> 1) , the sampling frequency for this well should be semiannually. <br /> 5. Table B-2, Wells LM058AU, LM066A, and LM093AU <br /> Table B-2 indicates that wells LM025AUA, LM066A, and LM093AU are "not <br /> within 100 feet of an extraction well. " However, the coordinates in the <br /> Annual Monitoring Report, Table 2.5-1, indicate that LM025AUA is 80 feet <br /> from EW034AU, that LM066A is 41 feet from EW021A, and that IM093AUA is <br /> 10 feet from EW036AU. Please revise Table B-2 accordingly and reassess <br /> the sample frequency for these wells. <br /> 6. Table B-2, Well LM070C <br /> Table B-2 indicates the nearest extraction well to LM070C is EW013C. <br /> However, the nearest extraction well, as shown on Figure 3-2A, appears <br /> to be EW031C, located approximately 900 feet to the west. However, <br /> another well, TW013C, is located immediately adjacent to LM070C, as <br /> shown on Figure 3-2A, but it is not clear if this is an extraction well. <br /> Please clarify which extraction well is closest to LM070C. <br /> 7. Table B-2, Well LM095AU <br /> Analyses for VOCs and SVOCs should be included in. the analyses for <br /> samples from LM095AU to be consistent with ROD, Table 9-2. <br /> 8. Table B-2, Well LM097AU <br /> Please summarize the rationale in Table B-2 for dropping semiannual <br /> analyses for simazine and dioxins/furans that were performed in 1998. <br /> The Site-Wide Comprehensive ROD, Section 9.7.4 (SWMU 8) , does not <br /> specify criteria for discontinuing these analyses, and Table 9-2 of the <br /> ROD identifies groundwater monitoring for these soil contaminants. <br /> 9. Table B-2, Well LM163A <br /> Please include the sampling frequency rationale for LM163A in Table B-2 . <br /> 10. Table B-2, Wells LM166AU and LM167AU <br /> Dioxins/furans have been dropped from the analyses for 1999, following <br /> ROD criterion (Site-Wide Comprehensive ROD, Sections 9.7.3 .6 and <br /> 9.7.3 .8) of at least two consecutive semiannual samples, which were <br /> analyzed in 1998. However, please consider that the five-year review <br /> 3 <br />