110 Second Avenue Sou #137,Pacheco,CA 94553 <br /> McCAMPBELL ANALYTICAL INC. Telephone:510-798-1620 Fax:510-798-1622 <br /> 24 http://www.mccampbell.com E-mail:main@mccampbell.com <br /> POST-REACTION DECAY STUDY <br /> Dissolved ozone concentrations ranged from 0.029-0.066 mg/L during the reaction time interval&are tabulated in the <br /> results section. It decreased to ND(<0.005 mg/L)4 days after its generation was stopped. <br /> Dissolved hexachrome did not decay during the seven day post-reaction decay study. Its initial value of 7 is roughly <br /> equivalent to the 8.4 ppb found in the Final water, as a significant volume of water was removed for Final water testing <br /> &200m] DI added back into in the reaction vessel. The post-reaction day 1 to day 7 data scatter(2.1 to 7.0 ppb) is far <br /> greater than our —5% precision for hexachrome by 218.6 & this indicates that as yet not understood variables <br /> (aliquoting or filtering)are important. <br /> DISTLC&TTLC hexachrome remained ND during the post-reaction decay study. <br /> IMPROVEMENTS IN FUTURE EXPERIMENTAL TECHNIQUE <br /> The following improvements will be made to future experimental technique. <br /> 1)Glassware should be pre-ozonated&pre-cleaned to ND<0.2 ppb hexachrome levels. <br /> 2)A higher aquifer water to soil ratio should be used to eliminate water volume issues. 2:1 instead of 1:1 appears to be <br /> more suitable. <br /> 3)Ozone flow rates will be regulated more carefully to prevent changes such as that found on day 5 of the experiments. <br /> 4) TTLC hexachrome RL can be lowered to 80 ug/kg & possibly to 20 ug/kg. 800ug/kg was found to not be useful, <br /> although the 20-80 ug/kg limits may also not be useful. The DISTLC hexachrome RL may be able to be lowered to <br /> 24 ug/kg,which would be much more useful than 20 ug/kg. <br /> 5)We could test 5 consecutive days of the experiment next time instead of Days 1,2&5 only <br /> 6) The parallel N2 purge experiment should be performed in a 1L reaction vessel instead of 30ml U-shaped sparge <br /> vessel & can be purged with 02 or N2 instead of 03. Conditions should be the same as for the ozonated sample <br /> except that the ozone scrubber should be placed in front of the reaction rather than behind it. The water should be <br /> acidified to pH<2 to prevent bacterial decomposition if 02 is used. Insufficient soil was available for these <br /> procedures this time. <br /> 7)Aqueous phase metals sampling should be more standardized, in terms of time sample sits unpreserved, exactness in <br /> preservative's final acidity, whole container as opposed to aliquot acidification, & if necessary techniques for <br /> sediment removal. <br /> 8) Aqueous hexachrome sampling should be performed more carefully, taking into account time standing prior to <br /> filtration& filtration procedures. <br /> Bill,if you have any questions or comments please call. <br /> Yours truly, <br /> Edward Hamilton,Lab Director for McCampbell Analytical Inc. <br />