Laserfiche WebLink
j f <br /> I y { <br /> 27 Apnl 2003 <br /> `• AGE-NC Project No 96-0235 <br /> Page 6of8 <br /> TPH-d was detected in samples collected from MW-1, MW-2, MW-9, MW-10, MW-11A, <br />' MW-11B,MW-14B,MW-15A,MW-15B,EW-1 and EW-2 at concentrations as high as 7,100 µg/1 <br /> (MW-10) ' t <br />' BTEX compounds were detected in samples MW-1,MW-2,MW-10,EW-1 and EW-2 at maximum <br /> concentrations of 620 µg/1 benzene, 1,300 µg/1 toluene, 800 µg11 ethylbenzene and 3,100 µg/1 <br />' xylenes, in the sample from EW-1 <br /> MTBE was detected in the water samples collected from MW-9, MW-10, MW-11B, MW-12B, <br />' MW-13(A and B), MW-14B and EW-1 at concentrations ranging from 5 8 µg/1 (MW-13A) to <br /> 250 µg/l (EW-1) TBA was detected in the water samples collected from MW-6B and MW-14B at <br /> concentrations of 9 8 µg/1 and 11 µg/1, respectively Water samples analyzed from MW-1, MW-2, <br />' MW-5,MW-6B,MW-7,MW-8A,MW-11B,MW-12B,MW-13B,MW-14B and EW-2 contained <br /> detectable concentrations of 1,2-DCA ranging from 0 54 µg/1 (MW-8A) to 24 µg/1 (MW-14B) <br /> Concentrations ofDIPE,ETBE,TAME and EDB were not detected above laboratory reporting limits <br />' in any of the water samples collected during the December 2002 monitoring event <br /> Analytical results of water samples'collected during the fourth quarter of 2002 are summarized on <br /> lie Table 2 and 3, analytical results from previous monitoring events are summarized on Tables 4 and " <br /> 5 Figures 4 and 5 illustrate the ground water contamination plumes in upper and lower ground water <br /> intervals, respectively The laboratory report (MAI Lab IDs 0212433-001 through 0212433-024), <br />' chain-of-custody forms and the laboratory QA/QC report are included in Appendix D <br />' 4.0. SUMMARY AND CONCLUSIONS <br />' Based on the data collected from the former UST cluster area, AGE finds ' <br /> • Target analytes were not detected above laboratory reporting limits in the soil samples <br /> collected from pilot borings MW-14B and MW-15B I <br /> • The ground water flow in the area of the former UST cluster was in an inward-radiating <br /> pattern, with-a`net flow towards the-east-northeast in the upper monitored interval and- - <br /> towards the east in the lower monitored interval <br /> • TPH-g was detected in ground water samples collected from MW-10 and EW-1 at <br /> concentrations of 700 µg/1 and 14,000 µg/, respectively TPH-d was detected in samples . <br /> collected from MW-9,MW-10, MW-11(A and B), MW-14B,MW-15(A and B) and EW-1 <br /> at concentrations as high as 7,100 µg/1 (MW-10) <br />' BTEX compounds were detected in water samples collected from MW-10 and EW-1 The <br /> • maximum BTEX concentrations were detected in the sample from EW-1,,however the <br />' Advanced GeoEnvironmental,Inc <br />